8.3.4.6. Color Uniformity of White FieldUsing the white field test pattern (X’=3794, Y’=3960, Z’=3890), measure the chromaticitycoordinates of the center points of a 3 x 3 grid with a spectroradiometer.8.3.4.7. Sequential ContrastThe sequential contrast ratio is computed by dividing the white luminance (of a peakwhite field) by the black luminance (of a black field). The nominal (reference) value isrequired to have a minimum sequential contrast of 2000:1. The tolerances for masteringand exhibition are shown in Table 11: Reference Image Parameters and Tolerances. Inorder to eliminate unwanted detail or discoloration in near blacks, it is critical thatMastering Projectors have an equal or higher sequential contrast than all exhibitionprojectors.Note that this is a measurement of the sequential contrast of the system. It includes theprojector and the ambient light on the screen.<strong>DCI</strong> <strong>Digital</strong> <strong>Cinema</strong> System Specification v.1.2 Page 83