REMOVING AN EXISTING APPLIANCEWhen replacing an existing appliance, the resulting installation must comply with all local codes, or inthe abscence of local codes, to the National Fuel Gas Code ANSI Z223.1 and/or CAN/CGA B149installation codes and these installation instructions. If the installation of this furnace requires that anexisting appliance be removed from a venting system which still serves another gas fired appliance,this may require that the existing vent be re-sized. The following steps shall be performed with eachappliance connected to the venting system placed in operation while any other appliance connectedto the venting system are not in operation;a) Seal any unused openings in the venting system;b) Inspect the venting system for proper size and horizontal pitch, as required in the National Fuel GasCode, ANSI Z223.1 or the CAN/CGA B149 Installation Codes and these instructions. Determine thatthere is no blockage or restriction, leakage, corrosion and other deficiencies which could cause anunsafe condition;c) In so far as practical close all building doors and windows and all doors between the space inwhich the appliance(s) connected to the venting system are located and other spaces in the building.Turn on clothes dryers and any other appliance not connected to the venting system. Turn on anyexhaust fans such as range hoods and bathroom exhausts, so they shall operate at their maximumspeed. Do not operate a summer exhaust fan. Close fireplace dampers;d) Follow lighting instructions. Place the appliance being inspected in operation. Adjust thethermostat so the appliance shall operate continuously;e) Test for draft hood equipped appliance spillage at the relief opening after five (5) minutes of burneroperation. Use the flame of a match or candle;f) After it has been determined that each appliance connected to the venting system properly ventswhen tested as outlined above, return all doors, windows, exhaust fans, fireplace dampers and anyother gas-burning appliance back to their previous condition of use;g) If improper venting is observed during any of the above tests, the venting system must becorrected.If re-sizing of the existing vent is required this shall be sized in accordance with Appendix G of theNational Fuel Gas Code, ANSI Z223.1 or CAN/CGA B149 Installation Codes.IO-176 24

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!