164. <strong>TDS</strong> Mode4.1 Selecting <strong>TDS</strong> Mode1. Select <strong>TDS</strong> Mode ( → F3:Mode → F3:<strong>TDS</strong>).2. The <strong>900</strong>-C now proceeds to <strong>TDS</strong> measurement mode. Note that the decimal point will bereplaced by a “ ∗ ” until a successful calibration has been performed (see section 4.8).4.2 Selecting <strong>TDS</strong> readout in terms of NaCl or KClThe factory default setting for this item is NaCl. If this is satisfactory, go directly to section 4.3.1. Select the Display Units configuration menu ( → F5:Configure → F1:Units).2. Press to display <strong>TDS</strong> in terms of NaCl (Sodium Chloride).Press to display <strong>TDS</strong> in terms of KCl Potassium Chloride).Press to quit without changing the current setting.NoteThe difference between the NaCl and KCl settings is the formula used for converting the<strong>Conductivity</strong> reading from the sensor to a <strong>TDS</strong> reading. Set this function for the predominant salt inthe sample solution. All <strong>TPS</strong> <strong>TDS</strong> and Salinity standards are made up using NaCl.4.3 Setting the <strong>TDS</strong> calibration standardThe factory default for this item is 2000 ppM. If this is satisfactory, go directly to section 4.4.1. Select the <strong>TDS</strong> Standard entry ( → F5:Configure → F2:Standard).The following screen is now displayed…<strong>TDS</strong> Standard:2000 ppMRange 20 ppM to 500 ppK {2000}2. Type in the value of the <strong>TDS</strong> standard that is to be used for calibration, including the decimalpoint. Use the key to make any corrections. Be sure to enter the value of the standard at theselected reference temperature (see section 4.4).3. Press to save the value of the standard solution.Alternatively, press to quit without changing the current setting.4. The <strong>900</strong>-C will now ask you to enter the units for the <strong>TDS</strong> standard…<strong>TDS</strong> Standard:1000Select Units F1:ppMF2:ppK5. The <strong>TDS</strong> standard is now programmed for use at calibration.4.4 Setting the Reference TemperatureThe factory default setting for this item is 25 O C. If this is satisfactory, go directly to section 4.5.1. Select the ATC configuration menu ( → F5:Configure → F3:ATC).2. Press to reference all readings to 25 O C for Automatic Temperature Compensation.Press to reference all readings to 20 O C for Automatic Temperature Compensation.Press to quit without changing the current setting.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!