4.8 <strong>TDS</strong> CalibrationBefore attempting a <strong>TDS</strong> calibration, ensure that the <strong>900</strong>-C has been set up correctly, according tosections 4.1 to 4.7. The calibration procedure detailed below uses the sample configurations shownin sections 4.1 to 4.7.Also ensure that Temperature has been correctly calibrated (see section 7.1). A “ ∗ ” in theTemperature readout in place of the decimal point indicates that Temperature is NOT calibrated.1. Plug the <strong>TDS</strong> sensor into the CELL socket and the temperature sensor into the TEMP socket.(The separate temperature sensor is not required for combination <strong>TDS</strong>/Temperature sensors.)2. Rinse the <strong>TDS</strong> and temperature sensors in distilled water. Shake off as much water as possible.Blot the outside of the sensor dry. DO NOT BLOT THE ELECTRODE PLATES.Zero Calibration3. Let the sensor dry in air.4. Select <strong>TDS</strong> Calibration ( → F1:Calibrate → F1:<strong>TDS</strong>).5. The <strong>900</strong>-C will recognise the low <strong>TDS</strong> signal and attempt a Zero calibration. For example…0*01ppM k=1*00 25.0 O cPress Enter to Zero probe or Menu Exit.6. When the reading has stabilised at or near zero, press to calibrate or to quit. The ∗will not be removed after a zero calibration.Standard Calibration7. Place the <strong>TDS</strong> sensor into a sample of <strong>TDS</strong> standard, so that it is immersed correctly, withadequate clearance to the floor and walls of the vessel. See section 17.2 for details of correctsensor immersion.DO NOT place the sensor directly into the bottle of standard. Discard the used sample ofstandard after use.Select <strong>TDS</strong> Calibration ( → F1:Calibrate → F1:<strong>TDS</strong>). The calibration screen willbe displayed, with the <strong>TDS</strong> standard to be used. For example…2000*ppM k=1*00 25.0 O cPress Enter to Calibrate. STD=2000 ppM.8. When the reading has stabilised, press to calibrate. The ∗ will now be replaced by adecimal point, if calibration was successful.9. The <strong>900</strong>-C is now calibrated for <strong>TDS</strong> and is ready for use in this mode.19

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!