<strong>EVA</strong>A field replaceable, three-part plunger seal providesthe wear surface between the plungerassembly <strong>and</strong> the plunger.A filter eliminates any contaminants from enteringthe pump’s plunger system.Air from the pressurized plunger system is ventedthrough an externally adjustable relief valve poppetlocated at the high point of the plunger system.A replenishment valve/replenishment check worktogether to insure excellent suction lift.1.5 STROKE LENGTH ADJUSTMENT ASSEM-BLYThe stroke length is fully adjustable from 0% to100% in 1% increments. The adjuster is fullysealed to prevent contamination or oil leakage.Also the stroke adjuster can be easily converted toan electronic stroke adjuster.1.6 GENERAL SPECIFICATIONSFlow Rate:0.049 GPH (0.18 L/H) to 23 GPH (88.5 L/H)Pressure:Up to 3500 PSIG (241 BAR)Turn Down Ratio:10:1 (optional 100:1)Steady State Accuracy:±0.5% of flow settingRepeatability:± 2% of full flowLinearity:± 1% of full flowMaximum Temperature:Metallic to 250 F (121 C)Non-metallic to 150 F (66 C)Paint:Powder Coating° °° °2