<strong>EVA</strong>• Pressure Port: 1/4 NPT (F) 316SSElectrical Connection• 1/2 NPT(M); 18 in. (458) mm) str<strong>and</strong>edwire leads, 18-AWG color-coded <strong>and</strong>marked.Temperature Limits° ° ° °° ° ° °• Process: 32 to 400 F (0 to 204 C)• Ambient: -40 to 167 F (-40 to 75 C)Electrical Service (Notes 2 <strong>and</strong> 3)• For DPDT contact form, replace EF inmodel number with EG. Multiply typicaldead b<strong>and</strong> by 2.• 250 VAC - 5 amp• 30 VDC - 5 amp• 125 VDC - 0.5 ampShipping WeightNotes:• Approximate 1 lb (0.5 kg)1. Other wetted materials <strong>and</strong> pressure port sizesare available. Consult your representative orthe SOR representative in your area for moreinformation.2. The DC electrical ratings are for resistive loadsonly. DC ratings are not agency approved orlisted but have been verified by testing orexperience.3. The hermetically sealed switching elementcapsule is UL Listed, CSA Certified <strong>and</strong> SSAApproved as an explosion proof snap switchper the following table DIMENSIONS:.AgencyUL ListedCSA CertifiedSAAApprovedTable 6.Agency ApprovalsHazardous Location ConditionsClass I, Group A, B, C, & DClass II, Group E, F, & GDivision 1 & 2Ex s IIC T6 for Class I, Zone 1DIP Type B 80°C for Class II, Div.1 & 2Figure 19. Pressure Switch Dimensions.DIMENSIONS:Linear = MMINDimensions (Figure 19) are for reference only.Contact the factory for certified drawings for a particularmodel number.ELECTRICAL CONNECTIONUse a 1-1/8 in (29 mm) open-end wrench to holdthe hex on the electrical connection while conduitor conduit fitting is being tightened.The electrical switch element capsule assemblycontains UL Listed <strong>and</strong> CSA Certified factorysealedleads. A conduit seal is not required to preserveexplosion proof integrity. Electrical leads aremarked NC (normally Closed), NO (NormallyOpen) <strong>and</strong> C (Common). Electrical switching elementsare snap-action <strong>and</strong> are either SPDT orDPDT (2-SPDT) set to actuate simultaneously(See diagram next page).24

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!