Chapter 4 Maintenance<strong>Series</strong> <strong>830</strong>/<strong>840</strong>/<strong>860</strong> Instruction ManualValve MaintenanceElectromagnetic valves may require spring-tension adjustments forvarious reasons (See Valve Adjust Procedure). No maintenance isrequired under normal operating conditions other than an occasionalcleaning. Use of certain corrosive gases may require frequentreplacement of the valve plug <strong>and</strong> O-rings. This indicates aneed for a different elastomer. Viton is st<strong>and</strong>ard, with Neoprene,Kal-Rez (or equivalent), <strong>and</strong> PFA Teflon offered as options.Do not attempt any valve adjustments while the meter is “on-line”with any dangerous gas. All controllers should be thoroughly leaktestedfollowing any valve adjustment.For the Model <strong>860</strong> Auto-Trak, refer to “Piston Tube CalibrationProcedure” for instructions on how to re-adjust the electromagneticvalve for proper operation.Electromagnetic Valves - Low <strong>and</strong> Medium Flow ControllersControllers with a low or medium flow body use the same valve;high flow models use a larger version. Cleaning can often be accomplishedby opening the valve, using the purge function <strong>and</strong>flushing in both directions. Alternatively, the valve may be manuallyopened by loosening the 6-32 lock nut on top of the valve <strong>and</strong>turning the adjustment screw fully counterclockwise.To disassemble the low <strong>and</strong> medium flow valve for inspection:Caution!When using toxic or corrosivegases, purge theunit thoroughly with inertdry gas before disconnectingfrom the gas line.1. Remove the unit from the system.2. Remove the two 4-40 Phillips head screws on top of the enclosure.Remove the enclosure by sliding it up <strong>and</strong> off. Removethe metal cap on top of the valve by inserting a flat tip screwdriverinto the slots provided <strong>and</strong> prying upward.3. Use a 5/8 inch nut driver to loosen <strong>and</strong> remove the 5/8 inchnut at the top of the valve. Remove the coil, coil enclosure <strong>and</strong>warp washer.4-8 IM-83/84/86-H

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!