13.07.2015 Views

MSQ - SMC Pneumatics (Ireland)

MSQ - SMC Pneumatics (Ireland)

MSQ - SMC Pneumatics (Ireland)

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Basic WiringSeries <strong>MSQ</strong>Auto Switch Connections and ExamplesSolid state 3-wire, NPNMainswitchcircuitBrownLoadBlackBlueSolid state 3-wire, PNPMainswitchcircuitBlackBrownBlueLoad2-wireMainswitchcircuitLoadBrownBlue2-wireIndicatorlight,protectioncircuit,etc.BrownLoadBlue(Power supplies for switch and loadare separate.)MainswitchcircuitBrownLoadBlackBlueMainswitchcircuitBrownLoadBlueIndicatorlight,protectioncircuit,etc.BrownBlue LoadExamples of Connection to PLC (Programmable Logic Controller)Sink input specifications3-wire, NPNBrownSwitchBlack InputSource input specifications3-wire, PNPBrownSwitchBlackInputConnect according to the applicablePLC input specifications, as theconnection method will vary dependingon the PLC input specifications.BlueBlue2-wireBrownCOMInputPLC internal circuit2-wireBlueCOMInputPLC internal circuitSwitchSwitchBlueCOMPLC internal circuitBrownConnection Examples for AND (Series) and OR (Parallel)3-wireAND connection for NPN output(using relays)Switch 1Switch 2BrownBlackBlueBrownBlackBlueRelayRelayLoadRelaycontactSwitch 1Switch 2BrownBlackBrownCOMAND connection for NPN output(performed with switches only)BlueBlackBlueLoadPLC internal circuitOR connection for NPN outputSwitch 1Switch 2BrownBlackBlueBrownBlackBlueLoad2-wire with 2 switch AND connectionSwitch 1Switch 2BrownBlueBrownBlueLoadWhen two switches areconnected in series, a loadmay malfunction becausethe load voltage will declinewhen in the ON state.The indicator lights willlight up if both of the switchesare in the ON state.Load voltage at ON =Power supplyResidualvoltage voltagex 2 pcs.= 24 V 4 V x 2 pcs.= 16 VExample: Power supply is 24 VDCVoltage drop in switch is 4 VThe indicator lights will light up whenboth switches are turned ON.2-wire with 2 switch OR connectionSwitch 1Switch 2BrownBlueBrownBlueLoadWhen two switchesare connected inparallel, malfunctionmay occur becausethe load voltage willincrease when inthe OFF state.Load voltage at OFF =Leakagex 2 pcs. x Loadcurrentimpedance= 1 mA x 2 pcs. x 3 kΩ= 6 VExample: Load impedance is 3 kΩLeakage current from switch is 1 mABecause there is no currentleakage, the load voltagewill not increase when turnedOFF. However, dependingon the number of switchesin the ON state, the indicatorlights may sometimesget dark or not light up,because of dispersion andreduction of the current flowingto the switches.26

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!