13.07.2015 Views

Indoor Unit - Toshiba

Indoor Unit - Toshiba

Indoor Unit - Toshiba

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

9. TECHNICAL SPECIFICATIONS<strong>Indoor</strong> unit (50Hz specifications)• 4-way Air Discharge Cassette Type50HzModel name MMU- AP0091H AP0121H AP0151H AP0181H AP0241H AP0271H AP0301H AP0361H AP0481H AP0561HCooling/Heating capacity (Note 1) (kW) 2.8/3.2 3.6/4.0 4.5/5.0 5.6/6.3 7.1/8.0 8.0/9.0 9.0/10.0 11.2/12.5 14.0/16.0 16.0/18.0Power supply1 phase 50Hz 230V (220 – 240V) (Power exclusive for indoor is required.)ElectricalcharacteristicsRunning current (A) 0.17 0.19 0.21 0.24 0.35 0.59 0.81 0.83Power consumption (kW) 0.020 0.022 0.026 0.032 0.048 0.070 0.110 0.112Starting current (A) 0.30 0.33 0.36 0.42 0.59 0.87 1.23 1.26AppearanceMain unitCeilingPanelHeat-insulating material attached Zinc hot dipping steel plateModelRBC-U21PG (W)-EPanel color Moon white (Munsell/2.5GY 9.0/0.5)Height (mm) 256 319Main unit Width (mm) 840OuterdimensionDepth (mm) 840Height (mm) 35CeilingpanelWidth (mm) 950Depth (mm) 950Total weightMain unit (kg) 20 22 23 28Ceiling panel (kg) 4.5Heat exchangerSoundproof/Heat-insulatingmaterialFanFinned tubeNon-flammable insulationTurbo fanFan unitStandard air flow High(Mid./Low)(m³/h)800(730/680)930(830/790)1,050(920/800)1,200(920/820)1,320(1,110/850)1,680(1300/1,070)2,040(1,430/1,130)2,090(1,520/1,230)Motor (W) 60 90Air filterControllerStandard filter attached (Long life filter)Remote controllerConnectingpipeGas side (mm) Ø9.5 Ø12.7 Ø15.9Liquid side (mm) Ø6.4 Ø9.5Drain port (Nominal dia.) 25 (Polyvinyl chloride tube)Sound level(Note 2)High (Mid./Low)(dB(A)) 30/29/27 31/29/27 32/29/28 34/31/28 37/33/30 40/36/33 44/38/34 45/40/34Note 1 : The cooling capacities and electrical characteristics are measured under the conditions speciied by JIS B 8615 based on thereference piping. The reference piping consists of 5 m of main piping and 2.5 m of branch piping connected with 0 meter height.Note 2 : The sound level are measured in an anechoic chamber in accordance with JIS B8616. Normally, the values measured in theactual operating environment become larger than the indicated values due to the effects of external sound.Note : Rated conditions Cooling : <strong>Indoor</strong> air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DBHeating : <strong>Indoor</strong> air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB40

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!