50HzOutdoor unit (50Hz)Equivalent HP Equivalent to 8HP Equivalent to 10HP Equivalent to 12HPModel name MMY- MAP0801FT8 MAP1001FT8 MAP1201FT8Outdoor unit typeInverter unitCooling capacity ( 1) (kW) 22.4 28.0 33.5*Standard heating capacity ( 1) (kW) 25.0 31.5 35.5*Power supply ( 2) 3 phase 50Hz 400V (380 – 415V)*Running current (A) 9.25 13.15 19.85Power consumption (kW) 6.07 8.54 12.90Cooling Power factor (%) 95 96 94EER (Energy Efficiency Ratio) (kW/kW) 3.69 3.28 2.60ElectricalStarting current (A) 1.0 1.0 1.0characteristicsRunning current (A) 9.55 13.40 14.85(* 1) Power consumption (kW) 6.29 8.73 9.65Heating Power factor (%) 95 96 94EER (Energy Efficiency Ratio) (kW/kW) 3.97 3.61 3.68Starting current (A) 1.0 1.0 1.0External dimension (mm) Height 1,800 x Width 990 x Depth 750Total weight (kg) 263ColorSilky shade (Munsell 1Y8.5/0.5)CompressorTypeHermetic typeMotor output (kW) 2.3 × 2 3.1 × 2 4.2 × 2FanPropeller fanFan unitMotor output (kW) 0.60Air volume (m³/h) 9,900 10,500Heat exchangerFinned tubeRefrigerant R410A (Charged refrigerant amount) ( 3)*(kg) 14.0High-pressure switch (MPa) OFF : 2.90 ON : 3.73Protective devices (* 5)Discharge gas side (mm) Ø19.1Suction gas side (mm) Ø22.2 Ø28.6Connecting port diaLiquid side (mm) Ø12.7Balance pipe ( 6)*(mm) Ø9.5Discharge gas sideBrazingSuction gas sideBrazingConnecting methodRefrigerant pipingLiquid sideFlarespecifications (* 4) Balance pipe (* 6)FlareMax. equivalent length (m) 125100 (However, if equivalent bend length is longer, equivalent length isMax. real length(m)the standard.)Max. total pipe length (Real length) (m) 250Outdoor unit is higher than indoor unit : 50Max. height difference(m)Outdoor unit is lower than indoor unit : 30Control wiringShield wire 1.25mm² x 2 cores. up to 2000mWhen connecting to outdoor unit :Central remote controller(Shield wire) 1.25mm² x 2 cores. up to 1000m and(Shield wire) 2.0mm² x 2 cores. up to 2000mMax. No. of connected indoor units 13 16 16Sound level (dB(A)) 57 58 59* 1 : Rated conditions Cooling : <strong>Indoor</strong> air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DBHeating : <strong>Indoor</strong> air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WBThe standard piping measns that main pipe length is 5 m, branching pipe length 2.5 m of branch piping connected with a 0 meter height.2 : The source voltage must not fluctuate more than ±10%.3 : The amount does not consider extra piping lengths. Refrigerant must be added on site in accordance with the actual piping length.4 : The maximum total piping length indicates the sum of one-way piping lengths on the liquid side or gas side.* 5 : Discharge temp. sensor, Suction temp. sensor, Compressor case thermostat, High-pressure switch, Over-current sensor, Highpressuresensor, Low pressure sensor, Over-current relay.*50

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!