439440441442443444445446biased high because of positive matrix interference. In cases where the sample was analyzed byboth EPA Method 314.0 and SW-846 Method 8321A Modified, Shaw reported the perchlorateresult from the EPA SW-846 Method 8321A Modified analysis. This is because EPA SW-846Method 8321A Modified provides greater method sensitivity and minimizes the possibility offalse positives. The table below summarizes perchlorate results reported by both EPA Method314.0 and SW-846 Method 8321A Modified, and Westons calculated relative percent difference(RPD) values. A low RPD value indicates good reproducibility or precision between perchlorateresults analyzed by both EPA Method 314.0 and SW-846 Method 8321A Modified.Sample ID EPA Method 314.0Result ( g/L)EPA SW-846 Method8321A ModifiedResult ( g/L)Relative PercentDifference (RPD)GW-DW002 < 1.0 0.46 NCGW-MW007 3.84 4.2 9GW-MW012