Uplift tests were conducted on toe-nailed <strong>roof</strong> <strong>fram<strong>in</strong>g</strong>-to-wall <strong>connections</strong> and on modified<strong>connections</strong>. The modifications were chosen to represent retrofitt<strong>in</strong>g alternatives available forhomeowners to improve the w<strong>in</strong>d resistance of <strong>roof</strong> <strong>fram<strong>in</strong>g</strong>-to-wall <strong>connections</strong>. Three testswere conducted on rafter-to-wall <strong>connections</strong> us<strong>in</strong>g three 16d box toe-nails. It should be notedthat this configuration is stronger than the three 8d common toe-nails required by current code[27]. The <strong>fram<strong>in</strong>g</strong> lumber species was Douglas-fir hav<strong>in</strong>g an average tested specific gravity of0.45. A mean value of 668 lb with a standard deviation of 63 lb was recorded for the upliftcapacity of the connection.Reed et al. [28] <strong>in</strong>vestigated the uplift capacity of rafter-to-top plate <strong>connections</strong> <strong>in</strong> light-framewood <strong>construction</strong>. The results were used to evaluate the resistance of <strong>in</strong>dividual <strong>connections</strong> touplift loads caused by severe w<strong>in</strong>d events. Connections fastened with hurricane straps, toe nails,and adhesives were tested. Over 350 tests were performed on 28 different <strong>roof</strong>-to-wallconnection details. A total of 13 tests were conducted on the standard toe-nail connection us<strong>in</strong>gSPF lumber and three 8d common toe-nails per jo<strong>in</strong>t. This connection had an average withdrawalcapacity of 410 lb and a standard deviation of 139 lb (COV = 0.34) <strong>in</strong> the assembly tests. Forcomparison, Equation 1 predicts an ultimate uplift capacity of about 200 lb to 280 lb, assum<strong>in</strong>g a<strong>fram<strong>in</strong>g</strong> lumber specific gravity of 0.37 to 0.42, a nail penetration of about 1 <strong>in</strong>ch, and no toenailreduction factor as required by NDS-97. The mode of failure reported for the toe-nailed<strong>connections</strong> was nail withdrawal.2.3 CONCLUSIONS ON LITERATURE SURVEYResults of the literature survey of research <strong>in</strong>formation relevant to the performance and methodsof analysis of nailed wood <strong>connections</strong> <strong>in</strong> <strong>residential</strong> <strong>roof</strong> <strong>construction</strong> <strong>in</strong>dicate that a volum<strong>in</strong>ousbody of knowledge is accumulated <strong>in</strong> this field. However, there is a disparity <strong>in</strong> bothunderstand<strong>in</strong>g the response and the state-of-the-art of the eng<strong>in</strong>eer<strong>in</strong>g design methods betweenvarious connection configurations, failure modes, and design applications. While a soundmethodology exists for analysis of withdrawal resistance of <strong>in</strong>dividual nail <strong>connections</strong> andmultiple nail <strong>connections</strong> with<strong>in</strong> <strong>roof</strong> systems, there is a lack of rational application of the designmethodologies for lateral analysis of nail <strong>connections</strong>. The capacity-based design philosophy forwood shear <strong>connections</strong> is advocated and analytical methods for determ<strong>in</strong>ation of connectioncapacity are proposed [2], yet little experimental data is compiled to substantiate theimplementation of capacity-based design <strong>in</strong>to the eng<strong>in</strong>eer<strong>in</strong>g design procedures. As an <strong>in</strong>tegralpart of capacity-based design, a practical method for model<strong>in</strong>g the nail load-slip relationshipshould be adopted. Moreover, current design methods ignore systematic aspects of theperformance of the nail shear <strong>connections</strong> with<strong>in</strong> multiple nail jo<strong>in</strong>ts and structural systems thatuse a cumulative resistance of multiple jo<strong>in</strong>ts with the exception of the nail diaphragm factor [1].Determ<strong>in</strong>ation of these system effects for <strong>conventional</strong> <strong>construction</strong> is the key for understand<strong>in</strong>gthe generally successful historic performance of <strong>conventional</strong> light-frame wood <strong>construction</strong> andis necessary for development of methodologies that accurately predict the response of<strong>conventional</strong> systems for efficient design of houses.An experimental research program was developed to beg<strong>in</strong> address<strong>in</strong>g some of the identifieddeficiencies and <strong>in</strong>equities <strong>in</strong> the current design methodologies relevant to the objectives of thisstudy. The purpose of this program was to <strong>in</strong>vestigate the response parameters <strong>in</strong>clud<strong>in</strong>g capacityand stiffness of <strong>conventional</strong> <strong>roof</strong> <strong>connections</strong> with the focus on the system performance9

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!