777 12 TH STREET, 3 RD FLOOR (916) 874-4800SACRAMENTO, CA 95814-1908 FAX (916) 874-4899PERMIT TO OPERATEISSUED TO:XXX AUTO BODYEQUIPMENT LOCATION: XXXXXXXXXX ST., SACRAMENTO, CA 95820PERMIT NO.XXXXXEQUIPMENT DESCRIPTIONPAINT SPRAY BOOTH, MAKE: EAGLE, MODEL: SDD 26-14-9-SP, 18’-11”W x 26’-3”L x11’-1”H, 2 EXHAUST FANS AT 2 HP EACH, DRY FILTER-TYPE, HVLP APPLICATIONSUBJECT TO THE FOLLOWING CONDITIONS:GENERAL1. The equipment shall be properly maintained and operated in accordance with the manufacturer’srecommendations at all times.[Basis: SMAQMD Rule 201, Section 405]2. The <strong>Air</strong> Pollution Control Officer and/or authorized representatives, upon the presentation of credentialsshall be permitted:A. To enter upon the premises where the source is located or in which any records are required to be keptunder the terms and conditions of this Permit to Operate, andB. At reasonable times to have access to and copy any records required to be kept under terms andconditions of this Permit to Operate, andC. To inspect any equipment, operation, or method required in this Permit to Operate, andD. To sample emissions from the source or require samples to be taken.[Basis: SMAQMD Rule 201, Section 405]LARRY GREENEDATE ISSUED: 05-12-2012 AIR POLLUTION CONTROL OFFICERDATE EXPIRES: XX-XX-XXXX (UNLESS RENEWED)BY:PAGE 1 OF 9 PAGESPERMIT NOS.: XXXXXREVOCABLE AND NON-TRANSFERABLE
777 12 TH STREET, 3 RD FLOOR (916) 874-4800SACRAMENTO, CA 95814-1908 FAX (916) 874-4899SACRAMENTO METROPOLITANAIR QUALITY MANAGEMENT DISTRICT3. This Permit to Operate does not authorize the emission of air contaminants in excess of those allowed byDivision 26, Part 4, Chapter 3, of the California Health and Safety Code or the Rules and Regulations ofthe <strong>Sacramento</strong> <strong>Metropolitan</strong> <strong>Air</strong> Quality Management District (SMAQMD).[Basis: SMAQMD Rule 201, Section 405]4. The equipment shall not discharge such quantities of air contaminants or other materials which causeinjury, detriment, nuisance or annoyance to any considerable number of persons or to the public, or whichendanger the comfort, repose, health or safety of any such persons or the public, or which cause, or have anatural tendency to cause, injury or damage to business or property.[Basis: SMAQMD Rule 402, Section 301]5. A legible copy of this Permit to Operate shall be maintained on the premises with the equipment.[Basis: SMAQMD Rule 201, Section 401]EMISSIONS LIMITATIONS6. The coating operation shall not discharge into the atmosphere any visible air contaminants other thanuncombined water vapor, for a period or periods aggregating more than three minutes in any one hour,which are as dark or darker than Ringelmann No. 1 or equivalent to or greater than 20% opacity.[Basis: SMAQMD Rule 401, Section 301]7. The emissions from the coating operation shall not exceed the following limit:[Basis: SMAQMD Rules 201, Section 405 and Rule 202, Section 301 and 410.2]Pollutant (A)Maximum Allowable Emissionslb/day lb/quarter lb/yearVOC 861.8 (B) 4,700 4,700PM10 2.8 (C) 15 (C) 15 (C)PM2.5 2.8 (C) 15 (C) 15 (C)GHG 0 tons/day 0 tons/quarter 0 tons/year(A) Definitions: VOC is volatile organic compound as defined in SMAQMD Rule 101, General Provisionsand Definitions. PM10 is particulate matter with an aerodynamic diameter of 10 microns or less.PM2.5 is particulate matter with an aerodynamic diameter of 2.5 microns or less. GHG emissionfactor is the CO 2 e emission factor as per Tables C1 and C2 of Subpart C of EPA’s MandatoryReporting for Greenhouse Gases rule (40 CFR, Part 98).(B) Based on a coating spray rate of 6.3 gallons/hour (Binks HVLP gun maximum spray rate), maximumVOC content of 5.7 lbs/gallon (based on Rule 459 maximum standards), and operating 24 hours/day.(C) PM10 emissions are based on an uncontrolled emission factor of 6.4 lb PM10/ton of VOC emittedfrom <strong>Air</strong>s Facility Subsystem Source Classification Codes and Emission Factor Listing for Criteria <strong>Air</strong>Pollutants, March 1990, EPA 450/4-90-003. The PM10 emission factor is assumed to be all PM2.5.PAGE 2 OF 9 PAGESREVOCABLE AND NON-TRANSFERABLEPERMIT NOS.: XXXXX
- Page 1 and 2: Automotive, Truck and Heavy Equipme
- Page 3 and 4: Materials for Vehicles - The requir
- Page 5 and 6: 2. State Requirementsa. California
- Page 7 and 8: Temporary Protective Coating 60 (0.
- Page 9 and 10: Administrative/Recordkeeping Requir
- Page 11 and 12: 4. New Source Review -- Emission Of
- Page 13 and 14: - Supplied with manufacturer’s em
- Page 15 and 16: 777 12th Street, 3rd Floor SACRAMEN
- Page 17 and 18: Authority to Construct EvaluationA/
- Page 19 and 20: Authority to Construct EvaluationA/
- Page 21 and 22: Authority to Construct EvaluationA/
- Page 24 and 25: Exhibit VI-BSample Authority to Con
- Page 26 and 27: 777 12 TH STREET, 3 RD FLOOR SACRAM
- Page 28 and 29: 777 12 TH STREET, 3 RD FLOOR SACRAM
- Page 30 and 31: 777 12 TH STREET, 3 RD FLOOR SACRAM
- Page 32 and 33: 777 12 TH STREET, 3 RD FLOOR SACRAM
- Page 34 and 35: 777 12 TH STREET, 3 RD FLOOR SACRAM
- Page 38 and 39: 777 12 TH STREET, 3 RD FLOOR (916)
- Page 40 and 41: 777 12 TH STREET, 3 RD FLOOR (916)
- Page 42 and 43: 777 12 TH STREET, 3 RD FLOOR (916)
- Page 44: 777 12 TH STREET, 3 RD FLOOR (916)