3.4. MATERIALS AND METHODS 55Figure 3.12: Synchronization diagram. The electronic circuit in the middle enables thesynchronization of the mouse, webcam and acquisition system.which the <strong>de</strong>scribed electrical modification was performed.BVPThe blood volume pressure sensor was placed in the distal phalange of the ring finger onthe non-dominant hand. The sensor was placed in the finger supported by two small elasticbands. The sensor was adjusted until a signal appears with qualitative high amplitu<strong>de</strong>(i.e. we adjust the position until we obtain a signal where the heart beat cycle is clearlynoticeable in the monitor screen). Figure B.7 presents the sensor coupled to the hand inthe ring finger.ECGWe used a one lead ECG montage at the V2 <strong>de</strong>rivation, to <strong>de</strong>tect the subject heart beat.We placed a trio<strong>de</strong> electro<strong>de</strong>, with standard 2 cm spacing of Ag/AgCl contacts, in the 4thintercostal space in the mid clavicular line. The positioning place was prepared by cleaningwith alcohol and conductive paste was used in the electro<strong>de</strong>s for improved signal quality.A strap was used to hold the electro<strong>de</strong>s in the <strong>de</strong>fined position.