<strong>Pro</strong>/<strong>DIAGRAM</strong> - <strong>Help</strong> <strong><strong>To</strong>pic</strong> <strong>Collection</strong><br />

14<br />

Origin—Places the grid origin anywhere on the screen and shows coordinate<br />

axes at the current grid origin.<br />

Grid Params—Establishes the spacing and angle of the grid. The Cart Params<br />

menu appears with the following options:<br />

o X&Y Spacing—Sets the spacing in both X- and Y-direction to the same<br />

value.<br />

o X Spacing—Sets the X-spacing only.<br />

o Y Spacing—Sets the Y-spacing only.<br />

o Angle—Modifies the angle between the horizontal and the X-direction grid.<br />

Note: Before creating wires it is helpful to:<br />

Modify the grid parameters and/or the <strong>com</strong>ponent locations so that all the nodes<br />

are located on grid intersections.<br />

Click <strong>To</strong>ols > Environment and check Snap to Grid to turn the grid snap on.<br />

If you turn on the grid before creating connectors, it ensures that any pins (nodes)<br />

you create are on the grid and are spaced properly.<br />

<strong>To</strong> Switch Snap to Grid<br />

1. Select <strong>To</strong>ols > Environment. The Environment dialog box opens.<br />

2. In the Default Actions box, check or clear Snap to Grid and Snap to XY Axes<br />

as required.<br />

Note: If grid snap is on, objects only snap to the grid if the grid spacing is set<br />

large enough to be visible. On an A-size drawing, the grid is not visible if the grid<br />

spacing is less than 0.7 mm or 0.07 inches.<br />

The visibility of the drawing also depends on the size of the window and whether<br />

you have collapsed the left panel of the window or not.<br />

3. Click Apply or OK for the changes to affect your current diagram.<br />

<strong>To</strong> Set Default Conductor Names<br />

Use the <strong>Pro</strong>/<strong>DIAGRAM</strong> setup options to customize default names of the wires, cables,<br />

rails, and highways.<br />

1. Click File > <strong>Pro</strong>perties. The Options dialog box opens.<br />

2. Use the options below for wires as a guideline for all conductor objects; each<br />

object (highways and rails for example) uses similar setup options.<br />

o wire_default_prefix defines the prefix of wirenames. Use the characters<br />

that are allowed for parameters. The default value is WIRE.<br />

o wire_default_suffix defines the first number or letter of the wirename<br />

that is incremented as you add a new wire. The value must either be only

Hooray! Your file is uploaded and ready to be published.