<strong>Pro</strong>/<strong>DIAGRAM</strong> - <strong>Help</strong> <strong><strong>To</strong>pic</strong> <strong>Collection</strong><br />
36<br />
text. For example, &cable_name<br />
has no special meaning.<br />
CABLE_SHIELD_REPORT_NAME Use this name for the cable<br />
symbol if the cable is shielded.<br />
The default value is SHIELD.<br />
CABLE_NODE_REPORT_NAME Use this name for the nodes of a<br />
cable symbol. The default value<br />
is "-".<br />
SHIELD_LINEAR_RESISTANCE Specifies linear resistance of the<br />
wire's shielding.<br />
OUTER_SHIELD_LINEAR_RESISTANCE Specifies linear resistance of the<br />
wire's outer shielding.<br />
LIN_CAP_TO_ITEM Specifies linear electric capacity<br />
between items.<br />
LIN_CAP_ITEM_TO_SHIELD Specifies linear electric capacity<br />
between items and shield.<br />
LIN_CAP_ASSEM_ITEM_TO_SHIELD Specifies linear electric capacity<br />
between assembly items and<br />
shield.<br />
OUTER_SHIELD_THICKNESS Specifies thickness of the outer<br />
shielding of the wire.<br />
Individual Wire and Cable Parameters<br />
The following table lists the available parameters for individual wires and cables.<br />
These parameters are established when the wire or cable is created, but are not<br />
passed from the spool.<br />
NAME Indicates the name of the wire or cable. This<br />
value is read-only in the parameter field and<br />
is created automatically upon creation of a<br />
wire or cable. Click Edit > Value to change<br />
the name of the wire or cable. The value of<br />
this parameter updates automatically in the<br />
file.<br />
Format: NAME read-only_string<br />
Example: NAME CABLE0001<br />
SPOOL Indicates the spool used for a wire or cable.<br />
This value is read-only and is created<br />
automatically upon creation of a wire or<br />
cable. Select the wire or cable and click Edit