RRCastile-B FS Pellet Stove1Listing and Code ApprovalsA. Appliance Certification E. BTU & Efficiency SpecificationsModel:Laboratory:Report No.Type:Standard:Castile Pellet StoveOMNI Test Laboratories, Inc.061-S-77d-6.2Solid Fuel Room Heater/Pellet Fuel BurningTypeASTM E1509-04, ULC S627-00 and ULC/ORD-C1482-M1990 Room Heater PelletFuel Burning type and (UM) 84-HUD,Mobile Home Approved.B. Mobile Home ApprovedThis appliance is approved for mobile home installationswhen not installed in a sleeping room and when an outsidecombustion air inlet is used.The structural integrity of the mobile home floor, ceiling, andwalls must be maintained.The appliance must be properly grounded to the frame ofthe mobile home and use only Listed pellet vent Class “L”or “PL” connector pipe.A Quadra-Fire Outside Air Kit must be installed in a mobilehome installation. You must order the Outside Air Kit separately.Note: The appliance is also approved for installationinto a shop.C. Glass SpecificationsThis appliance is equipped with 5mm ceramic glass.Replace glass only with 5mm ceramic glass. Please contactyour dealer for replacement glass.D. Electrical Rating115 VAC, 60 Hz, Start 4.1 Amps, Run 1.1 AmpsNOTE: Some generator or battery back-up systemsmay not be compatable with the micro-processor electronicson this appliance. Please consult the powersupply manufacturer for compatable systems.Particulate EmissionsRating:*BTU Output:Heating Capacity:Hopper Capacity:Fuel:Shipping Weight:0.7 grams/hr8,000 - 30,000 / hrup to 1,500 sq. ft. dependingon climate zone40 lbs +/-5 lbsWood Pellets or Shelled Corn258 lbs*BTU output will vary, depending on the brand of fuel youuse in your appliance. Consult your Quadra-Fire dealerfor best results.WARNING! Risk of Fire! Hearth & Home Technologies disclaimsany responsibility for, and the warranty and agencylisting will be voided by the above actions.DO NOT:• Install or operate damaged appliance• Modify appliance• Install other than as instructed by Hearth & HomeTechnologies• Operate the appliance without fully assembling allcomponents• Overfire• Install any component not approved by Hearth &Home Technologies• Install parts or components not Listed or approved.Improper installation, adjustment, alteration, service ormaintenance can cause injury or property damage.For assistance or additional information, consult a qualifiedinstaller, service agency or your dealer.NOTE: Hearth & Home Technologies, manufacturer ofthis appliance, reserves the right to alter its products,their specifications and/or price without notice.Castile-B FS Pellet Stove2Getting StartedA. Design, Installation & Location Considerations1. Appliance LocationNotice: Check building codes prior to installation.• Installation MUST comply with local, regional, state andnational codes and regulations.• Consult insurance carrier, local building inspector, fireofficials or authorities having jurisdiction over restrictions,installation inspection and permits.It is a good idea to plan your installation on paper, usingexact measurements for clearances and floor protection,before actually beginning the installationConsideration must be given to:• Safety, convenience, traffic flow• Placement of the chimney and chimney connector.• If you are not using an existing chimney, place the appliancewhere there will be a clear passage for a factorybuiltlisted chimney through the ceiling and roof.• Installing an optional outside air kit would affect the locationof the vent termination.Location NOT recommended:• Not the highest point of the roof• Wind loading possibleWindwardRecommended Location:• Above peakMarginal Location:• Below peakRecommended:• Insulated exterior chasein cooler climatesRecommended Location:• Above peak• Inside heated spaceSince pellet exhaust can contain ash, soot or sparks, youmust consider the location of:• Windows• Air Intakes• Air Conditioner• Overhang, soffits, porch roofs, adjacent walls• Landscaping, vegetationWhen locating vent and venting termination, vent above roofline when possible.Warning! Risk of Fire Damaged parts could impair safeoperation. Do NOT install damaged, incomplete or substitutecomponents.CAUTION! If burning shelled field corn, you must use approvedventing specifically designed for corn to prevent corrosionor degradation. Follow the instructions from the ventingmanufacturer.Notice: Locating the appliance in a location ofconsiderable air movement can cause intermittent smokespillage from appliance. Do not locate appliance near:• Frequently open doors• Central heat outlets or returnsMarginal Location:• Wind loading possibleLocation NOT recommended:• Too close to tree• Below adjacent structure• Lower roof line• Avoid outside wallLeewardNOTE: This installation must conform with local codes.In the absence of local codes you must comply with theASTM E1509-95, ULC S627-00 ULC/ORD-C-1482-M1990 (UM) 84-HUDQuadra-Fire is a registered trademarkof Hearth & Home Technologies.Figure 5.1Recommended:Outside Air Intakeon windward sideMulti-level RoofsNOT recommended:Outside Air Intakeon leeward sidePage 4 7021-130D January 21, 2013January 21, 2013 7021-130D Page 5

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!