30.07.2015 Views

triad® electronic ballasts - Conserve-A-Watt Lighting, Inc

triad® electronic ballasts - Conserve-A-Watt Lighting, Inc

triad® electronic ballasts - Conserve-A-Watt Lighting, Inc

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

TRIAD ® ELECTRONIC BALLASTSFOR F48T12, F48T12ES, F60T12, F64T12 &F72T12 LAMPS• Standard & HighPerformance Models• Instant Starting Options• 1-2 Lamp ApplicationsSlimline LampsT12SLIMLINELamp Certification Line Input Power Ballast Ballast Min. F/CQty.StartingMethodLineVoltsCatalogNumberNOMCurrent(Amps)Power(<strong>Watt</strong>s)Factor(PF)Factor(BF)EfficacyFactor (BEF)THD%StartTempWiringDiag. Dim.F48T12 - One Lamp Applications1 IS 1200.39B260IUNVHP • •277 0.1847 > .95 1.10 2.34 < 10 0/-18 14 SLF48T12 - Two Lamp Applications120 B260I120RH • • 0.68 76 > .95 0.92 1.21 < 20 0/-18 14 ST2 PAR-IS 120 B260I120M-A • • 0.62 68 > .90 0.90 1.32 < 30 50/10 14 -A1200.61 75 > .981.27B260IUNVHP • •0.95277 0.27 74 > .95 1.28< 10 0/-18 14 SLF48T12ES - One Lamp Applications1 IS 1200.32 38 > .982.89B260IUNVHP • •1.10277 0.15 39 > .95 2.82< 10 60/16 14 SLF48T12ES - Two Lamp Applications120 B260I120RH • • 0.60 64 > .95 0.92 1.44 < 20 60/16 14 ST2 PAR-IS 1200.57 671.39B260IUNVHP • •> .95 0.93277 0.25 66 1.41< 10 60/16 14 SLF60T12 - One Lamp Applications120 B260I120RH • • 0.46 55 > .95 1.02 1.85 < 20 0/-18 14 ST1 PAR-IS 1200.49 > .98B260IUNVHP • •58277 0.22 > .951.10 1.90 < 10 0/-18 14 SLF60T12 - Two Lamp Applications120 B260I120RH • • 0.74 89 > .95 0.90 1.01 < 20 0/-18 14 ST2 PAR-IS 1200.77 921.00B260IUNVHP • •> .98 0.92277 0.33 91 1.01< 10 0/-18 14 SLF64T12 - One Lamp Applications120 B260I120RH • • 0.49 59 > .95 1.03 1.75 < 20 0/-18 14 ST1 PAR-IS 1200.51 61 > .981.80B260IUNVHP • •1.10277 0.35 96 > .95 1.15< 10 0/-18 14 SLF64T12 - Two Lamp Applications120 B260I120RH • • 0.80 95 > .95 0.90 0.95 < 20 0/-18 14 ST2 PAR-IS 1200.81 970.95B260IUNVHP • •> .98 0.92277 0.35 96 0.96< 10 0/-18 14 SLF72T12 - One Lamp Applications120 B260I120RH • • 0.60 66 > .95 1.04 1.58 < 20 0/-18 14 ST1 IS 1200.55 681.56B260IUNVHP • •> .95 1.06277 0.25 67 1.58< 10 0/-18 14 SLIS = Instant StartPRS = Programmed Rapid StartRS = Rapid StartOverall DimensionsMounting DimensionsDraw # L W H M XSL 11.75” 3.13” 1.78” 11.14” 2.00”-A 9.50” 1.70” 1.18” 8.89” 1.69”ST 9.50” 2.40” 1.55” 8.89” 1.69”STARTING METHOD LEGENDPAR-IS = Parallel Instant StartPAR-PRS = Parallel Programmed Rapid StartPAR-RS = Parallel Rapid StartSER-RS = Series Rapid StartWIRING DIAGRAMSFluorescent-ElectronicSTSL-AFor One Lamp Operation, Insulate one blue lead to 600VDIAGRAM 14PAGE 2- 41FOR MORE INFORMATION CALL1-800-BALLAST(225-5278)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!