30.07.2015 Views

triad® electronic ballasts - Conserve-A-Watt Lighting, Inc

triad® electronic ballasts - Conserve-A-Watt Lighting, Inc

triad® electronic ballasts - Conserve-A-Watt Lighting, Inc

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

T12SLIMLINESlimline Lamps• Standard & HighPerformance Models• Instant Starting Options• 1-2 Lamp ApplicationsTRIAD ® ELECTRONIC BALLASTSF72T12(cont.), F84T12, F96T12 & F96T12ESLAMPSFluorescent-ElectronicLamp Certification Line Input Power Ballast Ballast Min. F/CQty.StartingMethodLineVoltsCatalogNumberNOMCurrent(Amps)Power(<strong>Watt</strong>s)Factor(PF)Factor(BF)EfficacyFactor (BEF)THD%StartTempWiringDiag. Dim.F72T12 - Two Lamp Applications120 B260I120RH • • 0.92 107 > .95 0.90 0.84 < 20 0/-18 14 ST2 PAR-IS 120 B260I120M-A • • 0.90 105 > .95 0.90 0.86 < 30 50/10 14 -A1200.90 1090.83B260IUNVHP • •> .99 0.91277 0.39 107 0.85< 10 0/-18 14 SLF84T12 - One Lamp Applications120 B260I120RH • • 0.63 74 > .95 1.05 1.42 < 20 0/-18 14 ST1 IS 1200.63 761.45B260IUNVHP • •> .98 1.10277 0.28 75 1.47< 10 0/-18 14 -AF84T12 - Two Lamp Applications120 B260I120RH • • 1.02 120 > .95 0.88 0.73 < 20 0/-18 14 ST2 PAR-IS 1201.03 1230.72B260IUNVHP • •> .98 0.88277 0.44 120 0.73< 10 0/-18 14 -AF96T12 - One Lamp Applications120 B260I120RH • • 0.73 83 > .95 1.02 1.23 < 20 0/-18 14 ST1 IS 1200.70 851.24B260IUNVHP • •> .98 1.05277 0.31 84 1.25< 10 0/-18 14 SLF96T12 - Two Lamp Applications120 B260I120RH • • 1.16 133 > .95 0.86 0.65 < 20 0/-18 14 ST2 PAR-IS 1201.16 1390.63B260IUNVHP • •> .99 0.88277 0.50 137 0.64< 10 0/-18 14 SLF96T12ES - One Lamp Applications120 B260I120RH • • 0.60 66 > .95 1.05 1.59 < 20 60/16 14 ST1 IS 120 B260I120M-A • • 0.61 66 > .90 1.09 1.65 < 30 60/16 14 -A1200.59 721.43B260IUNVHP • •> .98 1.03277 0.26 70 1.47< 10 60/16 14 SLF96T12ES - Two Lamp Applications120 B260I120RH • • 0.93 107 > .95 0.88 0.82 < 20 60/16 14 ST2 PAR-IS 120 B260I120M-A • • 0.90 105 > .95 0.88 0.84 < 30 60/16 14 -A1200.96 1120.79B260IUNVHP • •> .99 0.88277 0.40 110 0.80< 10 60/16 14 SLIS = Instant StartPRS = Programmed Rapid StartRS = Rapid StartSTARTING METHOD LEGENDPAR-IS = Parallel Instant StartPAR-PRS = Parallel Programmed Rapid StartPAR-RS = Parallel Rapid StartSER-RS = Series Rapid StartOverall DimensionsMounting DimensionsDraw # L W H M XSL 11.75” 3.13” 1.78” 11.14” 2.00”-A 9.50” 1.70” 1.18” 8.89” 1.69”ST 9.50” 2.40” 1.55” 8.89” 1.69”WIRING DIAGRAMSSTSL-AFor One Lamp Operation, Insulate one blue lead to 600VDIAGRAM 14PAGE 2- 42FOR MORE INFORMATION CALL1-800-BALLAST(225-5278)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!