30.07.2015 Views

C2-Sewage Pumps DN 32 to DN 600 - 2008.pdf

C2-Sewage Pumps DN 32 to DN 600 - 2008.pdf

C2-Sewage Pumps DN 32 to DN 600 - 2008.pdf

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Sewage</strong> <strong>Pumps</strong> for Building ServicesElectrical accessories Wilo-DrainProduct descriptionsSwitchgear Wilo-EC-Drain 1x4.0Electronically controlled switchgear for the au<strong>to</strong>matic, transmitter-dependent control of1 wastewater/sewage submersible mo<strong>to</strong>r pumps of the Wilo-Drain series.• Full mo<strong>to</strong>r protection with integrated mo<strong>to</strong>r current moni<strong>to</strong>ring and thermal winding contactassessment• Lockable main switch• Transmitter connection for float switch, type WA65, WA 95• But<strong>to</strong>n for manual mode of the pump• High water alarm• Forced switch-on with high water• Potential-free fault signal (changeover contact) and potential-free operating signal (changeovercontact)• Integrated mains-dependent alarm buzzer• Operation, high water and malfunction display via LEDs in the front panelTechnical data:Operating voltage: 1~230 V, 3~400 V, 3~230 VConnected load P 2 : 4.0 kWMaximum current: 12AFrequency: 50/60 HzProtection class: IP 65 (within buildings/switch cabinets)Dimensions (W x H x D): 215 x 220 x 125 mmSubmersible Mo<strong>to</strong>r <strong>Pumps</strong>with Macera<strong>to</strong>rSubmersible Mo<strong>to</strong>r <strong>Pumps</strong>without Macera<strong>to</strong>rNote: Switchgears are not protected against explosions and may not be utilised except outsideof potentially explosive areas. Ex-uncoupling relays are <strong>to</strong> be provided for pump control in potentiallyexplosive areas.Switchgear Wilo-EC-Drain 2x4.0Microprocessor-controlled switchgear for the au<strong>to</strong>matic, transmitter-dependent control of2 wastewater/sewage submersible mo<strong>to</strong>r pumps of the series Wilo-Drain.• Mo<strong>to</strong>r protection by means of built-in thermal winding contact assessment• Lockable main switch• Transmitter connection for float switch, types WA65, WA 95 and MS 1• 2 but<strong>to</strong>ns for manual mode of the pumps• Adjustable pump kick function for a pump start of 3sec. after a standstill time of 7 days.• High water alarm• Forced switch-on with high water• Potential-free fault signal (changeover contact) and potential-free operating signal (changeovercontact)• Integrated mains-dependent alarm buzzer• Operation, high water and malfunction display via LEDs in the front panel• Optional for control of explosion-protected pumpsTechnical data:Operating voltage: 1~230 V, 3~400 V, 3~230 VConnected load P 2 : 2 x 4.0 kWMaximum current: 2 x 12AFrequency: 50/60 HzProtection class: IP 54Dimensions (W x H x D): 300 x 230 x 113mmElectrical AccessoriesWilo-DrainFlag4Note: Switchgears are not protected against explosions and may not be utilised except outsideof potentially explosive areas. Ex-uncoupling relays are <strong>to</strong> be provided for pump control in potentiallyexplosive areas.Flag5Wilo Catalogue <strong>C2</strong> – 50 Hz – <strong>Sewage</strong> <strong>Pumps</strong> <strong>DN</strong> <strong>32</strong> <strong>to</strong> <strong>DN</strong> <strong>600</strong>131

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!