30.07.2015 Views

C2-Sewage Pumps DN 32 to DN 600 - 2008.pdf

C2-Sewage Pumps DN 32 to DN 600 - 2008.pdf

C2-Sewage Pumps DN 32 to DN 600 - 2008.pdf

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Sewage</strong> <strong>Pumps</strong> for Building ServicesElectrical accessories Wilo-DrainProduct descriptionsSwitchgear Wilo-DrainControl PL 21 2Switchgear Wilo-DrainControl PL 2 WSSwitchgear for regulating the levels of 2 submersible mo<strong>to</strong>r pumps. Level measurement can becarried out with either the bubbling-through or the dynamic pressure procedure, via an electroniclevel sensor 0-2.5 mWs (4-20 mA) or float switch (WA65, WA 95 or MS1).• LCD display, multi-language switching• LED for alarm, operation/follow-up time, manual/au<strong>to</strong>matic operation• Potential-free contact for collective fault signal and high water alarm, pump malfunction 1,pump malfunction 2• Forced switch-on of the pump• Pump switch-off with follow-up time• Au<strong>to</strong>matic fault-actuated switchover• Integrated buzzer• Operating hours counter, pump startsTechnical data:Operating voltage: 1~230 V, 3~400 VFrequency: 50/60 HzProtection class: IP 65 (within buildings/switch cabinets)Dimensions (W x H x D): <strong>32</strong>0 x 300 x 120 mmNote: Switchgears are not protected against explosions and may not be utilised except outsideof potentially explosive areas. A level sensor in the Ex area (with breakdown barrier!) or a floatswitch (in the Ex area with Ex-uncoupling relay) is <strong>to</strong> be provided for pump control.Submersible Mo<strong>to</strong>r <strong>Pumps</strong>with Macera<strong>to</strong>rSubmersible Mo<strong>to</strong>r <strong>Pumps</strong>without Macera<strong>to</strong>r1 2Switchgear for regulating the levels of 2 submersible mo<strong>to</strong>r pumps.Level measurement can be carried out with either the bubbling-through or the dynamic pressureprocedure, via an electronic level sensor 0-1 mWs (4-20 mA) or float switch (WA65,WA 95 or MS 1).• LCD display, multi-language switching• LED for alarm, operation/follow-up time, manual/au<strong>to</strong>matic operation• Potential-free contact for collective fault signal and high water alarm, pump malfunction 1,pump malfunction 2• Forced switch-on of the pump• Pump switch-off with follow-up time• Au<strong>to</strong>matic fault-actuated switchover• Integrated buzzer• Operating hours counter, pump starts• Lockable main switch• 3~mains, no neutral conduc<strong>to</strong>r requiredElectrical AccessoriesWilo-DrainTechnical data:Operating voltage: 1~230 V, 3~400 VFrequency: 50/60 HzProtection class: IP 65 (within buildings/switch cabinets)Dimensions (W x H x D): <strong>32</strong>0 x 300 x 120 mmFlag4Note: Switchgears are not protected against explosions and may not be utilised except outsideof potentially explosive areas. A level sensor in the Ex area (with breakdown barrier!) or a floatswitch (in the Ex area with Ex-uncoupling relay) is <strong>to</strong> be provided for pump control.Flag5Wilo Catalogue <strong>C2</strong> – 50 Hz – <strong>Sewage</strong> <strong>Pumps</strong> <strong>DN</strong> <strong>32</strong> <strong>to</strong> <strong>DN</strong> <strong>600</strong>133

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!