30.07.2015 Views

C2-Sewage Pumps DN 32 to DN 600 - 2008.pdf

C2-Sewage Pumps DN 32 to DN 600 - 2008.pdf

C2-Sewage Pumps DN 32 to DN 600 - 2008.pdf

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Sewage</strong> <strong>Pumps</strong> for Municipal and Industrial ApplicationsPlanning GuideWilo submersible mixers and re-circulation pumps are approved foruse in potentially explosive areas. For this, the units are certifiedaccording <strong>to</strong> two different standards: The European ATEX standard aswell as the American FM standard.Atex standardThe units are constructed according <strong>to</strong> the “EU directive 94/ 09/EG”(ATEX 95) and the European standards DIN EN <strong>600</strong>79-0, EN <strong>600</strong>79-1.They may be operated in potentially explosive atmospheres whichrequire electrical devices of device group II, category 2.Thus, use in zone 1 and zone 2 is possible. These units may not beused in zone 0.Wilo submersible mixers and re-circulation pumps are characterisedas follows: II 2 G Ex d IIB T4-II = Device group IIMeaning: Meant for potentially explosive locations except for mines-2 = Category- G = Substance groupMeaning: Gases-Ex = Ex-protected device in acc. with European standard-d = Ignition protection class, mo<strong>to</strong>r housingMeaning: Pressure-proof enclosure- IIB = Explosion groupMeaning: For use <strong>to</strong>gether with gases of subdivision B, all gasesexcept for H2, <strong>C2</strong>H2, CS2- T4 = Temperature classMeaning: Max. surface temperature of the device is 135°CFM standardThe units are certified and approved by the recognised testing andapproval authority “FM Approvals” in accordance with the standardsFM 3<strong>600</strong>, 3615, 3615.80 and ANSI/UL-1004. They may be operatedin potentially explosive areas which require electrical devices with theprotection class “explosion-proof, class 1, division 1”. Thus, operationin areas with the required protection class “explosion-proof,class 1, division 2” according <strong>to</strong> the FM standard is also possible.Wilo submersible mixers and re-circulation pumps are characterisedas follows:Class 1; Division 1; Groups C, DClass 2; Division 1; Groups E, F, GClass 3T3C- Class 1; Division 1; Groups C, DMeaning: Gases, vapours, mists; explosive atmosphere present constantlyor occasionally during normal conditions; gas groups:Ethylene (C), propane (D)- Class 2; Division 1; Groups E, F, GMeaning: Dusts; Explosive atmosphere present constantly or occasionallyduring normal conditions; dust groups: Metal (E), carbon (F),grain (G)- Class 3Meaning: Fibres and lint- T3C = Temperature classMeaning: Max. surface temperature of the machine 160°CTemperature moni<strong>to</strong>ringStandard explosion-certified mo<strong>to</strong>rs are equipped with a temperaturemoni<strong>to</strong>r. This includes:- Mo<strong>to</strong>rs of size T 12 and T 13Winding: Temperature limiter 140°C- Mo<strong>to</strong>rs of size T 17 and T 20Temperature controller 130°C, temperature limiter 140°CThe temperature moni<strong>to</strong>r is <strong>to</strong> be connected so that au<strong>to</strong>matic reactivationcan occur when the “temperature controller” is triggered.When the “temperature limiter” is triggered, the reactivation shouldonly be possible when the “release but<strong>to</strong>n” has been pressed byhand.Frequency converter operationFor operation with a frequency converter, the mo<strong>to</strong>rs must beequipped with a PTC thermis<strong>to</strong>r temperature sensor. Specify theintended use when making your order so that we can equip themo<strong>to</strong>rs accordingly.Sealing chamber controlThe units can be equipped with external sealing chamber control.This can also be installed later. If the unit is equipped with an externalsealing chamber control, this may only be connected <strong>to</strong> an intrinsicallysafe electric circuit.Definition of the Ex zonesThe Ex zones are defined in the respective standards. The marking ofzones in the operating area of the units must be done by the opera<strong>to</strong>r.When ordering, indicate which Ex standard you are using as abasis and in which zone you want <strong>to</strong> operate the unit.FMAPPROVED150 Subject <strong>to</strong> change without prior notice 09/2007 WILO AG

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!