30.07.2015 Views

C2-Sewage Pumps DN 32 to DN 600 - 2008.pdf

C2-Sewage Pumps DN 32 to DN 600 - 2008.pdf

C2-Sewage Pumps DN 32 to DN 600 - 2008.pdf

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

l<strong>Sewage</strong> <strong>Pumps</strong> for Municipal and Industrial ApplicationsPlanning Guide<strong>Sewage</strong> pumps of the Wilo EMU product family have a modular structureand can be adapted <strong>to</strong> different requirements.Mo<strong>to</strong>rsThe mo<strong>to</strong>r housings are made of grey cast iron. The bearings of themo<strong>to</strong>r shaft are high-quality roller bearings. The mo<strong>to</strong>rs are designedfor insulation class “F” or “H”. For especially high demands againstcorrosion, the mo<strong>to</strong>rs can also be coated with Ceram, a liquid ceramicmaterial.CoolingThe mo<strong>to</strong>r cooling was realised in different ways. Depending on theconstruction, either oil, water/glycol or air is used as a heat carrier.Oil as well as water/glycol are cooled through a heat exchanger,which conducts the dissipated heat <strong>to</strong> the fluid. Air-filled T-mo<strong>to</strong>rsgive off heat directly <strong>to</strong> the environment via the housing.Mo<strong>to</strong>r overviewMo<strong>to</strong>rCoolantCooling and sealingsystemExFigure: Mo<strong>to</strong>r with active closed-circuit cooling and 2-chamber system for wetand dry sump installationF mo<strong>to</strong>rOil in the mo<strong>to</strong>r2-chamber systemwith passive closedcircuitcooling–FK mo<strong>to</strong>rOil in the mo<strong>to</strong>r2-chamber systemwith active closedcircuitcooling–FK 17.1 mo<strong>to</strong>rOil in the mo<strong>to</strong>r2-chamber systemwith active closedcircuitcooling•FO mo<strong>to</strong>rOil in the mo<strong>to</strong>r2-chamber systemwith passive closedcircuitcooling–FKT 27.1mo<strong>to</strong>rDry mo<strong>to</strong>r with water/glycol mixture in thecooling circuit2-chamber systemwith active closedcircuitcooling•FKT 49.../56... mo<strong>to</strong>rFKT 72 mo<strong>to</strong>rDry mo<strong>to</strong>r with oil inthe cooling circuitDry mo<strong>to</strong>r with oil inthe cooling circuit1-chamber systemwith active closedcircuitcooling2-chamber systemwith active closedcircuitcooling••Figure: Mo<strong>to</strong>r with active closed-circuit cooling and 2-chamber system for wetand dry sump installationHC mo<strong>to</strong>rDry mo<strong>to</strong>r with water/glycol mixture in thehermetically sealedcooling circuit2-chamber systemwith active closedcircuitcoolingT mo<strong>to</strong>r Air 1-chamber system •T 20.1 mo<strong>to</strong>r Air 1-chamber system ••The mo<strong>to</strong>rs with a closed-circuit cooling system can be operatedboth submerged and dry in permanent operation. T mo<strong>to</strong>rs can beimmersed in permanent operation, but can only be operated dry for ashort time. Thus, high process reliability is ensured.Figure: Dry mo<strong>to</strong>r for wet sump installation140 Subject <strong>to</strong> change without prior notice 09/2007 WILO AG

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!