30.07.2015 Views

C2-Sewage Pumps DN 32 to DN 600 - 2008.pdf

C2-Sewage Pumps DN 32 to DN 600 - 2008.pdf

C2-Sewage Pumps DN 32 to DN 600 - 2008.pdf

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Sewage</strong> <strong>Pumps</strong> for Building ServicesElectrical accessories Wilo-DrainProduct descriptionsAlarm switchgears Wilo-AlarmControl 1/2Wilo-AlarmControl 1:Mains-independent alarm system with shockproof plug. S<strong>to</strong>rage battery, acoustic alarm signal(buzzer), mini floater switch with 3 m cable mounted on the device. With potential-free contactand ISO housing IP 20.Wilo-AlarmControl 2:Mains-independent alarm system with shockproof plug and integrated outlet for connectingan appliance, e.g. a washing machine. S<strong>to</strong>rage battery, acoustic alarm signal (buzzer), minifloater switch with 3 m cable mounted on the device. With insulated housing IP 20.Technical data:- Operating voltage: 1~230 V, 50 Hz- Control voltage: 12 VDC (non-stabilised)-Alarm contact with AlarmControl 1: potential-free normally open contact,contact load max. 1 A (230 VAC)- Contact outlet: Contact load max. 16A (250 VAC)- Protection class: IP 20-Housing: ABS- Cable length mini-float switch: 3m (2 x 0.75mm 2 )-Maximum ambient temperature: + 60 °C- Dimensions (W x H x D): 68 x 112 x 53 mmSubmersible Mo<strong>to</strong>r <strong>Pumps</strong>with Macera<strong>to</strong>rSubmersible Mo<strong>to</strong>r <strong>Pumps</strong>without Macera<strong>to</strong>rNote: Switchgears are not protected against explosions and may not be utilised except outsideof potentially explosive areas.Mo<strong>to</strong>r protection plug CEEMo<strong>to</strong>r protection switch (only up <strong>to</strong> a nominal mo<strong>to</strong>r power of P 2 < 4 kW) with phase inverterand rotation direction indica<strong>to</strong>r, thermal mo<strong>to</strong>r protection of the mo<strong>to</strong>r. Performance ranges:• 2.6 – 3.7 A• 3.7 – 5.5 A• 5.5 – 8 A• 8 – 11.5 AOptional with TP 80, TP 100 assessment of thermal mo<strong>to</strong>r protection and leakage detectionpossible.Electrical AccessoriesWilo-DrainLevel sensorFor level determination.• Protection class 68• Measurement range 0 - 1 mWS; 0 - 2.5mWS• Cable lengths 10, 30 or 50 m• Output signal 4 - 20 mA• ATEX-certifiedFlag4Flag5Wilo Catalogue <strong>C2</strong> – 50 Hz – <strong>Sewage</strong> <strong>Pumps</strong> <strong>DN</strong> <strong>32</strong> <strong>to</strong> <strong>DN</strong> <strong>600</strong>135

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!