30.07.2015 Views

C2-Sewage Pumps DN 32 to DN 600 - 2008.pdf

C2-Sewage Pumps DN 32 to DN 600 - 2008.pdf

C2-Sewage Pumps DN 32 to DN 600 - 2008.pdf

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Sewage</strong> <strong>Pumps</strong> for Building ServicesElectrical accessories Wilo-DrainProduct descriptionsSwitchgear Wilo-DrainControl PL 1Switchgear for regulating the levels of 1 submersible mo<strong>to</strong>r pump. Level measurement can becarried out with either the bubbling-through or the dynamic pressure procedure, with floatswitches or electronic level sensors.• LCD display• LED for alarm, operation/follow-up time, manual/au<strong>to</strong>matic operation• Input terminals for connecting float switches (WA65, WA 95 or MS1) or for connecting a levelsensor 0-1 mWs (4-20 mA)• Potential-free contact for collective fault signal and high water alarm• Forced switch-on of the pump• Pump switch-off with follow-up time• Integrated buzzer• Operating hours counter, pump startsTechnical data:Operating voltage: 1~230 V, 3~400 VFrequency: 50/60 HzProtection class: IP 65 (within buildings/switch cabinets)Dimensions (W x H x D): 180 x 255 x 180 mmNote: Switchgears are not protected against explosions and may not be utilised except outsideof potentially explosive areas. A level sensor in the Ex area (with breakdown barrier!) or a floatswitch (in the Ex area with Ex-uncoupling relay) is <strong>to</strong> be provided for pump control.Switchgear Wilo-DrainControl PL 1 WSSwitchgear for regulating levels of 1 submersible mo<strong>to</strong>r pump in conjunction with the pumpsstations Wilo-DrainLift WS... Level measurement can be carried out with either the bubblingthroughor the dynamic pressure procedure, with float switches or electronic level sensors.• LCD display• LED for alarm, operation/follow-up time, manual/au<strong>to</strong>matic operation• Input terminals for connecting float switches (WA65, WA 95 or MS1) or for connecting a levelsensor 0-1 mWs (4-20 mA)• Potential-free contact for collective fault signal and high water alarm• Forced switch-on of the pump• Pump switch-off with follow-up time• Integrated buzzer• Operating hours counter, pump starts• Lockable main switch• 3~mains, no neutral conduc<strong>to</strong>r requiredTechnical data:Operating voltage: 1~230 V, 3~400 VFrequency: 50/60 HzProtection class: IP 65 (within buildings/switch cabinets)Dimensions (W x H x D): 180 x 255 x 180 mmNote: Switchgears are not protected against explosions and may not be utilised except outsideof potentially explosive areas. A level sensor in the Ex area (with breakdown barrier!) or a floatswitch (in the Ex area with Ex-uncoupling relay) is <strong>to</strong> be provided for pump control.1<strong>32</strong> Subject <strong>to</strong> change without prior notice 09/2007 WILO AG

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!