Air-Cooled System—Standard and Optional Features5.0 AIR-COOLED SYSTEM—STANDARD AND OPTIONAL FEATURES5.1 Air-Cooled, Self-Contained Systems—Standard Features5.1.1 Pump Down ControlThe compressor pump-down control is accomplished by a liquid-line solenoid valve used inconjunction <strong>with</strong> a low pressure switch.5.1.2 CondenserThe <strong>Liebert</strong>-manufactured low profile, direct drive propeller fan type air-cooled condenser providesquiet, efficient operation.It is constructed of aluminum <strong>with</strong> a copper tube and aluminum fin coil for corrosion resistance. Anintegral, factory-wired and tested control panel reduces installation time.5.2 Condenser Types5.2.1 Fan SpeedFan speed control utilizes a wave-chopper control to vary the air volume over the condenser coil,based on refrigerant head pressure. The fan motor next to the electrical panel is a single-phase,permanent split capacitor motor <strong>with</strong> motor speed adjusted in response to refrigerant pressure. Thebalance of fans on multi-fan units cycle on ambient thermostats. The control system providesrefrigerant head pressure control for outdoor ambients as low as -20°F (-28.9 °C).5.2.2 Variable Frequency DriveVFD condenser control system utilizes a variable frequency drive, inverter duty fan motor operatingfrom 0% to 100% motor RPM based on head pressure, sensed by refrigerant pressure transducers.VFD, ambient-temperature thermostat(s), motor overload protection and electrical control circuit arefactory-wired in the integral control panel. VFD controls the fan adjacent to the connection end of thecondenser and remains energized <strong>with</strong> active compressor operation. The balance of fans on multi-fanunits cycle on ambient thermostats. This system provides refrigerant head pressure control foroutdoor ambients as low as -20°F (-28.9°C).Surge Protection DeviceA surge protection device (SPD) is standard in the VFD condenser models only. Surge protection isnecessary because rooftop voltage supply often is not conditioned the same as the voltage supplyinside a data center. The SPD is designed to protect sensitive electronic condenser components fromhigh voltage transients, up to 25kVA/phase.An illuminated green LED indicates power supply is On and panel status is OK. An illuminated redLED indicates conditions require service and the SPD may require replacement to restore surgeprotection to the condenser.9

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!