Glycol-Cooled Data—60Hz14.0 GLYCOL-COOLED DATA—60HZTable 6System TypeGlycol-cooled data, 60HzBF or BE = DownflowBU or BK = UpflowSelf-Contained(Indoor Standard / DigitalCompressor)Glycol CooledSplit Systems(Standard Scroll Compressor)Indoor Unit BF/BU 046WG BF/BU 071WG BF/BU 036E BF/BU 060E* Net Capacity Data - Std Air Volume BTU/H (kW) BTU/H (kW) BTU/H (kW) BTU/H (kW)85°F DB, 65°F WB (29°C DB, 18°C WB) 33% RH80°F DB, 63°F WB (27°C DB, 17.2°C WB) 38% RHTotal 42,200 (12.4) 69,500 (20.4) 40,100 (11.7) 68,000 (19.9)Sensible 41,900 (12.3) 69,500 (20.4) 40,100 (11.7) 68,000 (19.9)Total 40,000 (11.7) 64,800 (19.0) 38,000 (11.1) 63,400 (18.6)Sensible 38,200 (11.2) 64,800 (19.0) 37,500 (11.0) 62,300 (18.3)75°F DB, 61°F WB (24°C DB, 16°C WB) 45% RHTotal 38,200 (11.2) 60,600 (17.8) 36,300 (10.6) 59,300 (17.4)Sensible 34,000 (10.0) 59,000 (17.3) 33,900 (9.9) 54,500 (16.0)* Net Capacity Data - Optional Air Volume85°F DB, 65°F WB (29°C DB, 18°C WB) 33% RHTotal 43,800 (12.8) 70,400 (20.6) 41,600 (12.2) 68,900 (20.2)Sensible 43,800 (12.8) 70,400 (20.6) 41,600 (12.2) 68,900 (20.2)80°F DB, 63°F WB (27°C DB, 17.2°C WB) 38% RHTotal 40,900 (12.0) 65,400 (19.2) 38,900 (11.4) 64,000 (18.8)Sensible 40,800 (12.0) 65,400 (19.2) 38,900 (11.4) 63,700 (18.7)75°F DB, 61°F WB (24°C DB, 16°C WB) 45% RHTotal 38,600 (11.3) 60,700 (17.8) 36,700 (10.8) 59,400 (17.4)Sensible 36,800 (10.8) 60,100 (17.6) 36,200 (10.6) 55,700 (16.3)Fan Data (Blower A12x9AT)**Std. Air, CFM (CMH) 1800 (3060) 2800 (4760) 1800 (3060) 2800 (4760)Std. Fan Motor, hp (kW) 0.75 (0.56) 2 (1.5) 0.75 (0.56) 2 (1.5)Opt. Air, CFM (CMH) 2300 (3910) <strong>3000</strong> (5100) 2300 (3910) <strong>3000</strong> (5100)Opt Fan Motor, hp (kW) 1 (0.75) 2 (1.5) 1 (0.75) 2 (1.5)Ext. Static, in. WG (Pa) 0.3 (75) 0.3 (75) 0.3 (75) 0.3 (75)Evaporator Coil (BF: A-Frame; BU: V-Frame)Face Area, ft. 2 (m 2 ) 6.67 0 (0.62) 6.67 0 (0.62) 6.67 0 (0.62) 6.67 0 (0.62)Rows 3 4 3 4Face Velocity, FPM (m/s) 255 (1.3) 405 (2.1) 255 (1.3) 405 (2.1)Electric Reheat 2 Stage (Stainless Steel, Fin Tubular) - StandardCapacity, BTU/H (kW) (incl. motor heat) 33,400 (9) 56,200 (15) 33,400 (9) 56,200 (15)Hot Water Reheat 180°F (82.2°C) E.W.T., 75°F (23.9°C) E.A.T. - Optional (Includes standard air volume & optionalfan motor hp)Capacity, BTU/H (kW) (incl. motor heat) 71,400 (20.9) 88,700 (26.0) 71,400 (20.9) 88,700 (26.0)Flow Rate, GPM (l/s) 5.0 (0.32) 5.0 (0.32) 5.0 (0.32) 5.0 (0.32)Pressure Drop, ft. (kPa) 16.9 (50.4) 16.9 (50.4) 16.9 (50.4) 16.9 (50.4)Hot Gas Reheat - Optional (Includes standard air volume & optional fan motor)Capacity, BTU/H (kW) (incl. motor heat) 42,600 (12.5) 54,900 (16.1) 42,600 (12.5) 54,900 (16.1)* Capacity data is certified to ASHRAE 127-2007 standard. Fan motor heat has been subtracted, resulting in net capacity.30

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!