Liebert® Challenger™ 3000 with Liebert iCOM® - Emerson Network ...

Liebert® Challenger™ 3000 with Liebert iCOM® - Emerson Network ...

Liebert® Challenger™ 3000 with Liebert iCOM® - Emerson Network ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

6.3 Water/Glycol Split System—Standard Features6.3.1 Water/Glycol-Cooled Condensing UnitsWater/Glycol-Cooled Systems—Standard and Optional FeaturesFactory-charged and sealed, the water-cooled condensing unit is ready to be installed quickly andeasily. The counter-flow coaxial condenser <strong>with</strong> two-way or three-way regulating valve designed for150 psi (1034.3 kPa) is matched to the heat rejection requirements of the compressor for a variety offlow rates and fluid temperatures.Condensing unit has a hot gas bypass standard feature that bypasses hot gas around the compressordirectly to the suction side of the compressor to provide capacity control and reduce compressorcycling. System includes liquid injection valve to maintain proper suction superheat.6.4 Water/Glycol-Cooled, Split System—Optional Features6.4.1 High PressureThe high pressure option for the condenser circuit consists of a 2-way or 3-way water regulating valveand condenser rated at 350 psig (2413 kPa) water pressure. This option is required in applications<strong>with</strong> large static heads.6.4.2 Factory-Installed Non-Fused Disconnect SwitchAllows unit to be turned off for maintenance. Disconnect switch is available on indoor condensingunits only.6.4.3 Pre-Charged Line Sets—3 Ton OnlyConsists of one pre-charged liquid line and one pre-charged insulated suction line of soft coppertubing. Each line has one male quick-connect coupling and one female quick-connect coupling <strong>with</strong> anaccess valve connection.Available in 15 ft. (4.6m) and 30 ft. (9.1m) lengths for interconnection of remote located condensermodule. Maximum recommended distance between evaporator and condenser <strong>with</strong> pre-charged linesets is 45 ft. (13.7m). For longer runs, use sweat adapter kit.6.4.4 Refrigerant-Line Sweat Adapter Kit3 Ton Only: Contains two suction and two liquid line compatible fittings that allow field-suppliedinterconnecting refrigerant lines to be used.6.5 Glycol-Cooled Systems—Standard Heat Rejection Devices for Self-Contained andSplit Systems6.5.1 Fan Speed Control DrycoolerThe <strong>Liebert</strong> manufactured Fan Speed Control drycooler is constructed of aluminum and featurescopper tubes and aluminum fin design. It is low profile, propeller fan type and provides quiet, troublefree heat rejection. The drycooler features a variable speed fan motor and a specially engineered solidstate fan speed transducer. The transducer senses the temperature of the leaving glycol andmodulates the speed of the fan to maintain proper glycol temperatures. An integral, factory-wired andtested control panel reduces installation time and includes drycooler and pump controls.6.5.2 Glycol Pump PackageThe glycol system includes a matching centrifugal glycol pump. It is mounted in a vented,weatherproof enclosure.13

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!