22.08.2015 Views

Liebert® Challenger™ 3000 with Liebert iCOM® - Emerson Network ...

Liebert® Challenger™ 3000 with Liebert iCOM® - Emerson Network ...

Liebert® Challenger™ 3000 with Liebert iCOM® - Emerson Network ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Air-Cooled Data—60Hz10.0 AIR-COOLED DATA—60HZTable 2System Type<strong>Liebert</strong> Challenger <strong>3000</strong> air-cooled data—60HzBF = DownflowBU = UpflowSelf-Contained(Indoor Standard / DigitalCompressor)Split Systems - Standard Scroll Compressorw/Outdoor Prop-FanCondensing Unitw/Indoor CentrifugalCondensing UnitIndoor Unit BF/BU 042A BF/BU 067A BF/BU 036E BF/BU 060E BF/BU 036E BF/BU 060ENet Capacity Data - Standard Air Volume * BTU/H (kW) BTU/H (kW) BTU/H (kW) BTU/H (kW) BTU/H (kW) BTU/H (kW)85°F DB, 65°F WB (29°C DB, 18°C WB) 33% RH80°F DB, 63°F WB (27°C DB, 17.2°C WB) 38% RH75°F DB, 61°F WB (24°C DB, 16°C WB) 45% RHTotal 44,500 (13.0 67,900 (19.9) 43,000 (12.6) 65,700 (19.2) 42,500 (12.5) 66,000 (19.3)Sensible 43,400 (12.7 67,900 (19.9) 43,000 (12.6) 65,700 (19.2 42,500 (12.5) 66,000 (19.3)Total 42,300 (12.4 63,800 (18.7) 40,900 (12.0) 62,200 (18.2) 40,100 (11.7) 62,500 (18.3)Sensible 39,700 (11.6 63,300 (18.5) 40,200 (11.8) 61,200 (17.9) 39,600 (11.6) 61,400 (18.0)Total 40,600 (11.9 60,500 (17.7) 38,900 (11.4) 59,300 (17.4) 38,200 (11.2) 59,600 (17.5)Sensible 35,300 (10.3 56,600 (16.6) 36,200 (10.6) 54,600 (16.0) 35,700 (10.5) 54,800 (16.1)Net Capacity Data - Optional Air Volume *85°F DB, 65°F WB (29°C DB, 18°C WB) 33% RHTotal 45,800 (13.4 68,200 (20.0) 48,800 (14.3) 66,000 (19.3) 43,900 (12.9) 66,300 (19.4)Sensible 45,800 (13.4 68,200 (20.0) 48,800 (14.3) 66,000 (19.3) 43,900 (12.9) 66,300 (19.4)80°F DB, 63°F WB (27°C DB, 17.2°C WB) 38% RHTotal 43,100 (12.6) 63,900 (18.7) 42,000 (12.3) 62,100 (18.2) 41,200 (12.1) 62,400 (18.3)Sensible 42,700 (12.5) 63,800 (18.7) 42,000 (12.3) 61,800 (18.1) 41,200 (12.1) 62,100 (18.2)75°F DB, 61°F WB (24°C DB, 16°C WB) 45% RHTotal 41,000 (12.0) 60,300 (17.7) 39,400 (11.5) 59,000 (17.3) 38,600 (11.3) 59,400 (17.4)Sensible 38,200 (11.2) 57,600 (16.9) 38,700 (11.3) 55,300 (16.2) 38,100 (11.2) 55,700 (16.3)Fan Data (Blower A12x9AT) **Std. Air, CFM (CMH) 1800 (3060) 2800 (4760) 1800 (3060) 2800 (4760) 1800 (3060) 2800 (4760)Std. Fan Motor, hp (kW) 0.75 (0.56) 2 (1.5) 0.75 (.56) 2 (1.5) 0.75 (.56) 2 (1.5)Opt. Air, CFM (CMH) 2300 (3910) <strong>3000</strong> (5100) 2300 (3910) <strong>3000</strong> (5100) 2300 (3910) <strong>3000</strong> (5100)Opt. Fan Motor, hp (kW) 1 (0.75) 2 (1.5) 1 (0.75) 2 (1.5) 1 (0.75) 2 (1.5)Ext. Static, in. WG (Pa) 0.3 (75) 0.3 (75) 0.3 (75) 0.3 (75) 0.3 (75) 0.3 (75)Evaporator Coil (BF: A-Frame; BU: V-Frame)Face Area, ft. 2 (m 2 ) 6.67 (0.62) 6.67 (0.62) 6.67 (0.62) 6.67 (0.62) 6.67 (0.62) 6.67 (0.62)Rows 3 4 3 4 3 4Face Velocity, FPM (m/s) 255 (1.3) 405 (2.1) 255 (1.3) 405 (2.1) 255 (1.3) 405 (2.1)Electric Reheat 2 Stage (Stainless Steel, Fin Tubular) - StandardCapacity, BTU/H (kW) (incl. motor heat) 33,400 (9) 56,200 (15) 33,400 (9) 56,200 (15) 33,400 (9) 56,200 (15)Hot Water Reheat 180°F (82.2°C) E.W.T., 75°F (23.9°C) E.A.T. - Optional (Includes standard air volume and optional fan motor hp)Capacity, BTU/H (kW) (incl. motor heat) 71,400 (20.9) 88,700 (26.0) 71,400 (20.9) 88,700 (26.0) 71,400 (20.9) 88,700 (26.0)Flow Rate, GPM (l/s) 5.0 (.32) 5.0 (.32) 5.0 (.32) 5.0 (.32) 5.0 (.32) 5.0 (.32)Pressure drop, ft. (kPa) 16.9 (50.4) 16.9 (50.4) 16.9 (50.4) 16.9 (50.4) 16.9 (50.4) 16.9 (50.4)* Capacity data is certified to ASHRAE 127-2007 standard. Fan motor heat has been subtracted, resulting in “net” capacity.22

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!