2.7 Comprehensive Monitoring SolutionsGuide Specifications—Nominal 3 or 5 ton Environmental Control System(For detailed guide specifications on these products, refer to information posted at www.liebert.com)<strong>Liebert</strong> SiteScan Web System<strong>Liebert</strong> SiteLink Module<strong>Liebert</strong> Nform<strong>Liebert</strong> IntelliSlot Cards (Part Numbers)• <strong>Liebert</strong> IntelliSlot Web (IS-WEBCARD, IS-WEBLB, IS-WEBLBDS)• <strong>Liebert</strong> IntelliSlot 485 Card (OC485-LBDS)• <strong>Liebert</strong> IntelliSlot Web/485 Card (OCWEB)Environmental Discrete Outputs Card (ENV-DO)Universal Monitor<strong>Liebert</strong> vNSA <strong>Network</strong> SwitchThe <strong>Liebert</strong> vNSA network switch is designed for connecting multiple Ethernet-ready devices andcomes in various models: vNSA8-iCOM, vNSA16-iCOM 13, vNSA8, vNSA16 14. The unit may have a<strong>Liebert</strong> iCOM display mounted on the front. Models <strong>with</strong> the <strong>Liebert</strong> iCOM permit interconnectingcooling units that are equipped <strong>with</strong> <strong>Liebert</strong> iCOM controls, allowing the units to communicate andfunction as a team and facilitating lead/lag operation.Leak Detection• Direct Read Module• Zone Sensor•Spot Sensor3.0 EXECUTION3.1 Installation of Environmental Control Units3.1.1 GeneralInstall environmental control units in accordance <strong>with</strong> manufacturer’s installation instructions.Install units plumb and level, firmly anchored in locations indicated, and maintain manufacturer’srecommended clearances.3.1.2 Electrical WiringInstall and connect electrical devices furnished by manufacturer but not specified to be factorymounted.Furnish copy of manufacturer’s electrical connection diagram submittal to electricalcontractor.3.1.3 Piping ConnectionsInstall and connect devices furnished by manufacturer but not specified to be factory-mounted.Furnish copy of manufacturer’s piping connection diagram submittal to piping contractor.3.1.4 Supply and Drain Water PipingConnect water supply and drains to air conditioning unit. Provide pitch and trap as manufacturer’sinstructions and local codes require.3.2 Field Quality ControlStartup environmental control units in accordance <strong>with</strong> manufacturer’s startup instructions. Testcontrols and demonstrate compliance <strong>with</strong> requirements.67

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!