↓SNR 2521↓ ⇒ ↓Retry ?↓<br />
Explanation Possible Causes Required Action<br />
Setup cannot proceed a. Improper sensor a. Follow 4.2.5<br />
because the indicated alignment<br />
sensor is not returning<br />
a valid height reading.<br />
* The number is<br />
arbitrary<br />
b.<br />
c.<br />
Sensor is not reading the<br />
ground or the target<br />
properly.<br />
Faulty sensor.<br />
b.<br />
c.<br />
Follow 4.2.5.<br />
Replace sensor.<br />
↓↓SN=0 det↓ ⇒ ↓Retry ?↓<br />
Explanation Possible Causes Required Action<br />
At least one sensor has The sensor(s) was not set up Replace sensor(s).<br />
been detected with properly at the factory.<br />
improper<br />
programming.<br />
factory<br />
↓Too Many↓ ⇒ ↓Retry ?↓<br />
Explanation Possible Causes Required Action<br />
The system has<br />
detected that too many<br />
sensors are connected.<br />
Too many sensors have been<br />
connected to the system.<br />
↓Bakwards↓ ⇒ ↓Retry ?↓<br />
Remove sensors, or setup the system<br />
manually.<br />
Explanation Possible Causes Required Action<br />
Boom moves in the a. Wiring or hydraulic a. Follow 4.3.3, 4.3.7<br />
wrong direction.<br />
plumbing problem.<br />
b. Extremely under-damped b. Add mechanical damping to<br />
boom.<br />
the boom and/or consult<br />
<strong>NORAC</strong>.<br />
↓TooHigh!↓ or ↓TooLow!↓ .⇒ ↓Retry ?↓<br />
Explanation Possible Causes Required Action<br />
Boom is positioned System Setup was started with Follow 4.2.3 a), 4.2.4 and 4.3.2 a-3).<br />
higher than 60" or the boom positioned too high<br />
lower than 30" or too low.<br />
22