20.01.2013 Views

2. Applicability - Spirent Knowledge Base - Spirent Communications

2. Applicability - Spirent Knowledge Base - Spirent Communications

2. Applicability - Spirent Knowledge Base - Spirent Communications

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

TASKIT PLTS<br />

Automated Test System Version 3.80<br />

Product Update


<strong>Spirent</strong><br />

541 Industrial Way West<br />

Eatontown, NJ 07724 USA<br />

Email: sales@spirent.com<br />

Web: http://www.spirent.com<br />

AMERICAS 1-800-SPIRENT • +1-818-676-2683 • sales@spirent.com<br />

EUROPE AND THE MIDDLE EAST +44 (0) 1293 767979 • emeainfo@spirent.com<br />

ASIA AND THE PACIFIC +86-10-8518-2539 • salesasia@spirent.com<br />

Page Part Number: 71-006680, Version A1<br />

Copyright© 2012 <strong>Spirent</strong>. All Rights Reserved.<br />

All of the company names and/or brand names and/or product names referred to in this document, in particular, the<br />

name “<strong>Spirent</strong>” and its logo device, are either registered trademarks or trademarks of <strong>Spirent</strong> plc and its<br />

subsidiaries, pending registration in accordance with relevant national laws. All other registered trademarks or<br />

trademarks are the property of their respective owners.<br />

The information contained in this document is subject to change without notice and does not represent a<br />

commitment on the part of <strong>Spirent</strong>. The information in this document is believed to be accurate and reliable;<br />

however, <strong>Spirent</strong> assumes no responsibility or liability for any errors or inaccuracies that may appear in the<br />

document.


1. Description<br />

1.1. Overview<br />

This document contains product modifications for the following applications:<br />

• TASKIT PLTS version 3.80, the <strong>Spirent</strong> Position Location Test System for LBS testing<br />

on the C2K-ATS platform.<br />

For a complete version history, refer to the PLTS User Manual included in the software<br />

installation package.<br />

IMPORTANT!<br />

This release requires license file for PosApp 3.0 (replacement of SimGEN). If you don't have this<br />

license file, DO NOT perform this upgrade and contact your local <strong>Spirent</strong> Support Representative.<br />

IMPORTANT!<br />

This release does NOT support the SR3452 V1, TAS3450, TAS5200, and TAS3460<br />

AirAccess units. Do not use this software version with configurations using those<br />

units.<br />

Only configurations that utilize the SR3452v2 and SR3462 AirAccess units should<br />

be upgraded with this software version.<br />

In addition, this release requires an SR3610 instrument as part of AirAccess. If your<br />

system is under an active Annual Support Agreement with <strong>Spirent</strong> and does not<br />

have an SR3610 instrument, contact your local <strong>Spirent</strong> Support Representative and<br />

submit a request.<br />

This release requires a license file for PosApp 3.0 (the replacement of SimGEN). If<br />

you do not have this license file, DO NOT perform the upgrade. Contact your local<br />

<strong>Spirent</strong> Support Representative for details.<br />

NOTE: This release of TASKIT PLTS does not require you to enter a new password.


<strong>2.</strong> <strong>Applicability</strong><br />

This Product Update applies to the following products:<br />

• TASKIT/PLTS<br />

• PLTS-SC-TP1<br />

• PLTS-SC-TP2<br />

• PLTS-AUT-GPS-TP1<br />

• PLTS-USER-PLANE<br />

• PLTS-OTA


3. Compatibility<br />

3.1. Required Minimum Versions<br />

• UDM V2 Version 4.7.1<br />

NOTE: To successfully use UDM for EV-DO tests, the EV-DO option must be enabled<br />

for that tool.<br />

• PosApp Version 3.00<br />

• AirAccess Version 4.30<br />

• SR5500 TestKit Version 3.51<br />

3.<strong>2.</strong> Compatible Versions<br />

The current release is compatible with the following <strong>Spirent</strong> products:<br />

• TASKIT C2K Version 7.0<br />

• TestDrive EV-DO Version 5.0<br />

• TestDrive II SC Version <strong>2.</strong>80


4. Installation<br />

4.1. Overview<br />

This release has been placed on the <strong>Spirent</strong> Communication Customer Service Center<br />

website: http://support.spirentcom.com. Use the e-mail address and password<br />

assigned to you by <strong>Spirent</strong> to log onto the Members section and select Download<br />

Software Uploads>Wireless to access this latest release.<br />

NOTE: If you have forgotten your password or do not have login information for the<br />

Customer Server Center website, click the Forgot Your Password? or New User link<br />

on the Main Customer Service Center webpage.<br />

NOTE: When installing TASKIT/PLTS Version 3.50, it is not necessary to log into the<br />

System Controller PC under the PLTS_USER account. Any user name can be created<br />

as long as it has administrative rights and SimUpdate.reg is run once from the new<br />

account.<br />

NOTE: This release does NOT support the SR3452 V1, TAS3450, TAS5200 and<br />

TAS3460 AirAccess units. Do not use this software version with configurations<br />

using those units.<br />

Only configurations that utilize the SR3452v2 and SR3462 AirAccess units should<br />

be upgraded with this software version.<br />

In addition, this release requires an SR3610 instrument as part of AirAccess. If your<br />

system is under an active Annual Support Agreement with <strong>Spirent</strong> and does not<br />

have an SR3610 instrument, contact your local <strong>Spirent</strong> Support Representative and<br />

submit a request.<br />

4.<strong>2.</strong> Installation Steps<br />

1. Step 1: Record Instrument Configuration<br />

Before installing TASKIT/PLTS Version 3.80, launch TASKIT/PLTS, open the<br />

Instrument Configuration window by selecting Config>Instrument Config and note<br />

or record the instruments present in the system. Save this information for use in<br />

Step 9 below.


<strong>2.</strong> Step 2: Upgrade/Install AirAccess C2K v4.30<br />

If the current installed AirAccess C2K does not include Version 4.30 (or later), you are<br />

required to install AirAccess C2K v4.30 software on the system Controller PC. To<br />

upgrade the AirAccess C2K v4.xx software, perform the following steps:<br />

a. Uninstall the currently installed version of AirAccess C2K v3.xx (or 4.xx) by<br />

selecting Start>Control Panel>Add/Remove Programs.<br />

Reboot the System Controller PC, if necessary.<br />

b. Upgrade AirAccess C2K installed on your system to v4.30 by following the steps<br />

in the AirAccess Product Update document. During installation, ensure that you<br />

select the option to install the application for Anyone who uses this computer<br />

(all users).<br />

c. Run AirAccess C2K and accept the terms of the License Agreement.<br />

d. Select Instrument>Enter Configuration, and make sure all instruments are<br />

configured properly.<br />

Note that AirAccess C2K v4.3x does not support TAS3460.<br />

3. Step 3: Install New AirAccess C2K Password (Optional)<br />

If you have been supplied with a new password for AirAccess C2K with this update<br />

package, it is necessary for you to install this password before using TASKIT/PLTS<br />

Version 3.80.<br />

To install the new password, launch the AirAccess C2K software and select<br />

Help>Enter Application Password.<br />

Note the same password is used by AirAccess C2K 3.xx (or 4.xx) software.<br />

4. Step 4: Upgrade to PosApp v3.00<br />

If PosApp v3.00 is not installed in the System Controller PC, install it from the<br />

downloaded TASKIT/PLTS installation package or the supplied TASKIT/PLTS<br />

installation CD under the PosApp v3.00 folder.<br />

After the PosApp v3.00 installation is complete, you need to install the license file<br />

for the GPS simulator. The GPS security dongle is no longer needed after upgrading<br />

to PosApp v3.00.<br />

To install the license file:<br />

a. Insert the PosApp Customer-specific Text Files CD. Select the sig_gen.txt and<br />

lservrc.txt files and copy them to the Controller PC under the following path:<br />

C:\Program files\<strong>Spirent</strong> <strong>Communications</strong>\Positioning Application.<br />

b. Run Positioning Application. The No License Found window displays, as shown in<br />

Figure 4-1.


Figure 4-1: No License Found Window<br />

c. Click the Install license file button, browse to the lservrc.txt file on the<br />

Controller PC. Make sure the license is accepted. PosApp will close and restart on<br />

its own.<br />

NOTE: This section applies to GSS6700 users only.<br />

If you are using a GSS6700 simulator, follow the steps below to upgrade the<br />

GSS6700 firmware. The new firmware improves the stability of the GSS6700<br />

simulator. If you are using any other model, skip this step.<br />

To upgrade GSS6700 firmware:<br />

1. Close all opened applications and select Start>All Programs>Positioning<br />

Application>USB Utilities>Flash Memory Update Tool.<br />

<strong>2.</strong> If the window shown in Figure 4-2 displays, check the GNSS Simulator USB cable<br />

connections.<br />

If this window does not display, proceed to the next step.


Figure 4-2: Select Unit Window<br />

d. In the Open File window shown in Figure 4-3, navigate to:<br />

\PosApp v3.00\GSS6700 Firmware\sbmr_02-03-0<strong>2.</strong>bin<br />

Figure 4-3: Open File Window<br />

e. Select the file and click the Load button, as shown in Figure 4-4.


Figure 4-4: Loading the File<br />

f. After the upgrade completes, the window shown in Figure 4-5 displays.<br />

Power cycle the GSS6700 simulator and click OK.<br />

Figure 4-5: Flash Memory Loaded Successfully<br />

3. Step 5: Install Universal DM V2 Version 4.70<br />

To update the currently installed version of Universal DM V2:<br />

a. If you received a Universal DM V2 CD, insert the CD into the Controller PC and the<br />

installation automatically begins and replaces the currently installed Universal<br />

DM V<strong>2.</strong><br />

You can download the latest Universal DM V2 from <strong>Spirent</strong> website and execute<br />

the Universal DM V<strong>2.</strong>exe application.<br />

b. At the end of the installation, the Controller PC automatically reboots.<br />

4. Step 6: Upgrade SR5500 TestKit<br />

If required, upgrade the SR5500 TestKit software installed on your system to version<br />

3.51 by following the steps in the SR5500 Product Update. After the upgrade is<br />

complete, run TestKit and connect to SR5500 and, if prompted, follow the<br />

instructions to upgrade the firmware.


5. Step 7: Enable Dual Core on PC (If applicable).<br />

NOTE: This step only applies to Dell Optiplex 620-745, 760, and 780.<br />

a. To check whether Dual Core is already enabled on the PC, go to the Windows<br />

Device Manager and select the Processors category.<br />

If Dual Core is enabled, there should be 2 processors listed under the Processors<br />

category.<br />

b. If the PC already has Dual Core enabled, skip the rest of this section. If the PC<br />

only has single core enabled, follow the steps below.<br />

c. Reboot the PC.<br />

While the PC is rebooting, press F2 to enter the BIOS Setup window.<br />

d. Browse to Performance>Hyper-Threading (or Performance>Multiple CPU Core).<br />

e. Enable Hyper-Threading (or Multiple CPU Core) by selecting On.<br />

Press Enter.<br />

f. Press ESC and select Save/Exit. The PC should now continue to reboot to<br />

Windows.<br />

g. After Windows starts, verify that the Dual Core is enabled by using Windows<br />

Device Managers (as shown in step 1).<br />

6. Step 8: Install TCU2Wrapper package.<br />

Install the TCU2Wrapper package from the downloaded TASKIT/PLTS installation<br />

package or the supplied TASKIT/PLTS installation CD under the TCU2Wrapper Install<br />

folder.<br />

7. Step 9: Uninstall TASKIT/PLTS<br />

Uninstall TASKIT/PLTS by selecting Start>Control Panel>Add/Remove Programs.<br />

Reboot the Controller PC, if necessary.<br />

8. Step 10: Install TASKIT/PLTS Version v3.80<br />

To update the currently installed version of TASKIT/PLTS:<br />

a. Download the TASKIT/PLTS v3.80 installation image from<br />

http://support.spirentcom.com and save the image onto your hard drive.<br />

Extract the image into a temporary directory and then execute the Setup.exe<br />

application from this temporary directory. Alternatively, if you have received a CD<br />

with this Product Update, insert it into the Controller PC and run the Setup.exe<br />

application from the CD.<br />

b. A Welcome window displays; beginning the installation process.<br />

Click the Next button to continue.<br />

c. The <strong>Spirent</strong> Software License Agreement displays.<br />

Review the terms of this license agreement, and select I accept the terms in the<br />

license agreement.<br />

Click the Next button to continue.


d. The next window prompts you to enter User Information; including the User Name<br />

and Organization.<br />

Select the option to install the application for Anyone who uses this computer<br />

(all users).<br />

Click the Next button.<br />

e. Select the folder where the TASKIT/PLTS software will be installed. We<br />

recommend that you use the default subdirectory.<br />

Click the Next button to continue.<br />

f. At this point, TASKIT/PLTS Setup is ready to begin installing the software.<br />

Click the Install button to begin this process.<br />

g. If prompted to install the HASP drivers during the installation, select Yes.<br />

h. A window displays confirming the installation is complete.<br />

Click Finish to close the window.


9. Step 11: Verify Hardware Connectivity.<br />

After completing the previous steps, verify the connectivity of all instruments in the<br />

PLTS system:<br />

a. Launch the TASKIT/PLTS Test Executive software and open the Instrument<br />

Configuration window by selecting Config>Instrument Config.<br />

b. Ensure that the hardware selected in this window match the hardware noted in<br />

Step 1.<br />

c. Click the Verify Hardware button and ensure that the software can successfully<br />

connect to all selected instruments.<br />

d. Close the window and proceed and save the changes.<br />

10. Step 12: Calibrate the system (if required).<br />

If the SR5500 firmware has been upgraded; you should perform a levels/timing<br />

calibration of the PLTS system.<br />

If you are unable to perform a timing calibration, you can use the PLTS default<br />

settings. PLTS automatically detects the model of impairments (SR5500 or<br />

SR5500M) and selects default values accordingly.<br />

NOTE: This re-calibration is strongly recommended any time the SR5500 firmware<br />

version is modified on the PLTS system.<br />

To reset timing calibration to default settings:<br />

1. Restart TASKIT/PLTS.<br />

a. Run the Timing Calibration Wizard and select the Reset tab, as shown in Figure<br />

4-6.<br />

Figure 4-6: Timing Calibration Wizard – Reset


. Click OK on the warning message. All timing calibration data is set to values<br />

reflecting the SR5500 model.<br />

Note: The default timing calibration values are based on SR5500 Version 3.01<br />

and may vary if other versions are installed.<br />

c. You have successfully completed the upgrade procedure.<br />

NOTE: CCF-Validated Suites<br />

Because CCF validation is completed only after commercial availability of a release,<br />

<strong>Spirent</strong> is unable to provide CCF validated suites for this release. After the CCF<br />

validation is completed, the officially validated suites will be posted on the <strong>Spirent</strong><br />

Communication Customer Service Center website at<br />

http://support.spirentcom.com; under the Download section for this release.<br />

4.3. Disabling Microsoft Update<br />

After installing Microsoft Security Essentials, Microsoft Update is enabled by default.<br />

Microsoft Update must be disabled on 8100 systems.<br />

4.3.1. Windows XP<br />

If you are running Windows XP, perform the following steps for both the Controller PC<br />

and/or the Client Laptop.<br />

<strong>2.</strong> Select Start>Control Panel>Performance and Maintenance>System.<br />

The System Properties window displays.<br />

3. Under the Automatic Updates tab, select the Turn off Automatic Updates option, as<br />

shown in Figure 4-7.


Figure 4-7: System Properties Window – Automatic Updates Tab<br />

4. Click OK to save the changes and exit the window.<br />

4.3.<strong>2.</strong> Windows 7<br />

If you are running Windows 7, perform the following steps for both the Controller PC<br />

and/or the Client Laptop.<br />

5. Select Start>Control Panel>System and Security>Windows Update>Change<br />

Settings. The Windows Update – Change Settings window displays.<br />

6. Under the Important Updates section, select Never check for updates, as shown in<br />

Figure 4-8.


Figure 4-8: Windows Update – Change Settings<br />

7. Click OK to save the changes and exit the window.<br />

8. If a “Windows update is turned off. Click to turn on.” message displays on the<br />

desktop, ignore it.


5. New Features<br />

This release of TASKIT PLTS includes the following new features:<br />

• Upgrade SimGEN v<strong>2.</strong>83 to PosApp v3.00.<br />

• Support for the new SR8048 Test Configuration Unit.<br />

PLTS Software supports the SR8048 for all test suites except OTA.<br />

• Support for Windows 7 platform.<br />

PLTS software now supports both Windows XP and Windows 7 platforms.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!