Edge Panel ring anchor<br />

Detail No. SFP 2-12<br />

<strong>Structural</strong> steel support beam<br />

under panels<br />

Overhanging <strong>Floor</strong> panels refer<br />

to Detail SFP 2-6 for maximum<br />

cantilever<br />

Rebate to be<br />

cut along the<br />

panel edge to grout<br />

in a ring anchor<br />

reinforcing bar<br />

refer to Detail<br />

SFP 2-13, below<br />

for rebate size<br />

Standard Ring anchor<br />

reinforcement in grout fill<br />

D12 ring anchor reinforcing bar<br />

Standard profiled rebate in<br />

<strong>Supercrete</strong> <strong>Structural</strong> <strong>Floor</strong> <strong>Panels</strong><br />

<strong>Structural</strong> steel support beam<br />

Refer SFP 2-6<br />

2.1.6.6 Site Cut Ring Anchor<br />

Rebates<br />

Where floor panels overhang support<br />

beams, or are free spanning without a<br />

support wall under the outside panel<br />

edge longitudinally, it is not possible to<br />

install a conventional ring anchor. In these<br />

situations, it is necessary to specify a rebate<br />

chase to be cut along the panel edges to<br />

grout a reinforcing bar into. See Detail<br />

SFP 2-12, above.<br />

17<br />

7 7<br />

22 16 22<br />

<strong>Supercrete</strong> <strong>Structural</strong> <strong>Floor</strong> <strong>Panels</strong><br />

150, 175, 200, 225, or 250mm panels<br />

M12 threaded rod bolted to<br />

structural steel support beam<br />

nut and washer countersunk into<br />

panel face 30mm max<br />

SFP 2012 28 Copyright © <strong>Supercrete</strong> Limited 2008<br />

H = d -10 mm<br />

Ring Anchor Steel<br />

Cleat detail<br />

NOTE:<br />

1) All dimensions are in mm<br />

2) d= <strong>Supercrete</strong> <strong>Structural</strong><br />

<strong>Floor</strong> Panel Depth<br />

3) Weld to steel support with 6mm<br />

CFW. (continuous fillet weld all<br />

around)<br />

Rebate details<br />

Detail No. SFP 2-13<br />

<strong>Floor</strong> Panel<br />

Depth (mm)<br />

Notch<br />

Depth<br />

150 55<br />

175 to 250 80<br />

Notch<br />

cut-out<br />

60<br />

10<br />

Notch<br />

depth<br />

A panel with a site cut end rebate is lifted into position.<br />

Depth of<br />

floor panel<br />

Ring Anchor Site Panel Notching detail<br />

<strong>Supercrete</strong><br />

<strong>Structural</strong> <strong>Floor</strong> Panel