31.01.2013 Views

laboratory catalogue - Wenk Lab Tec

laboratory catalogue - Wenk Lab Tec

laboratory catalogue - Wenk Lab Tec

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

1<br />

7. Heating and cooling technology<br />

Heating/Incubators<br />

Type Capacity Internal<br />

dimensions<br />

(W x D x H)<br />

756<br />

1<br />

Constant Climate Chamber Model HPP 108<br />

E & OE.<br />

www.wenk-labtec.com<br />

GENERAL CATALOGUE 2010/11<br />

Standard Features<br />

Memmert<br />

Ventilation and Control:<br />

- forced air, fan ventilation<br />

- adaptive, fuzzy-supported, multifunctional PID-controller, for stepless control of Peltier heating/cooling system -<br />

without refrigerant<br />

- autodiagnostic system with fault indication on temperature and humidity control<br />

- 2 x Class A, 4-wire circuit, Pt100 sensors, mutually monitoring and maintaining performance at the same<br />

temperature value<br />

- digital, 7-day, programme-timer with real time clock and precise minute setting<br />

- integrated timer for heating/cooling profiles of up to 40 ramps, each segment adjustable from 1 min. up to 999<br />

hours<br />

- digital display (LED) of all set parameters, such as temperature, day, time, humidity and set-up values - language<br />

chosen in setup<br />

- digital display of set /actual values: 0.1°C<br />

- GLP-compliant archiving of all relevant data, via 1024kB memory data logger<br />

- non-volatile memory<br />

- parallel printer interface (incl. real-time clock with date function) for all PCL3-compatible, ink-jet printers, providing<br />

GLP-compliant documentation<br />

- USB interface and Memmert "Celsius" software for programming and documentation<br />

- chip card control incl. one MEMoryCard XL with 32 kB (up to 40 ramps)<br />

- incl. works calibration certificate for +10°C and +37°C at 60% RH<br />

Humidifying and dehumidifying system:<br />

- active humidifying and dehumidifying from 10 to 90% RH with digital display (resolution : 0.5%, setting accuracy<br />

1% RH)<br />

- humidity supplied by distilled water from external tank using self-priming pump<br />

- humidification by hot steam generator<br />

- dehumidification by cold-trap using Peltier technology<br />

Multiple Overtemperature Protection<br />

- with audible and visual alarms in case of over-/under temperature and/or humidity, or empty water tank<br />

- independently working, digitally adjustable electronic overtemperature controller, TWW protection class 3.3<br />

- additional adjustable Auto-Safety-Function "ASF" for over- and undertemperature automatically following the set<br />

value at a preset tolerance range<br />

Textured Stainless Steel Housing:<br />

- fully insulated, stainless steel door with double locking and 4-point adjustment<br />

- inner glass door<br />

- rear panel: zinc-plated steel<br />

Interior:<br />

- easy-to-clean, hermetically welded, 1.4301 (ASTM 304) stainless steel interior, reinforced by deep-drawn ribbing,<br />

with 2 stainless steel wire shelves (HPP 749), 2 perforated stainless steel shelves (HPP 108)<br />

Heating- and cooling system:<br />

- energy-saving, Peltier heating-/cooling system integrated into the rear housing<br />

Temperature Range:<br />

- from +5°C up to +70°C<br />

- temperature variation in chamber at 10°C and 37°C: < ±0.4°C<br />

Voltage/Power Rating:<br />

- 230V (±10%) 50/60Hz<br />

Housing<br />

(W x D x H)<br />

litres mm mm kg W<br />

HPP 108 108<br />

560 x 400 x 480<br />

710 x 760* x 620<br />

66<br />

350<br />

HPP 749 749<br />

1040 x 600 x 1200 1190 x 825* x 1620 218<br />

1050<br />

* Depth without door handle, please add 38 mm<br />

E0 (X) Perforated stainless steel shelf<br />

Q1 IQ check list with works test data for unit as support for validation by customer<br />

Q3 Extra for FDA conformance software, "Celsius<br />

FDA-Edition"<br />

V1 Oven-linked authorisation card (user ID card)<br />

V2<br />

V4<br />

V3<br />

W4<br />

W6<br />

W7<br />

Interface RS485 (for cross linking of several devices) instead of USB<br />

MEMoryCard XL<br />

Temperature profile write/read unit for programming<br />

via PC, for writing to and reading from the chip card,<br />

up to 40 ramps<br />

Ethernet interface instead of RS 232 Software<br />

"Celsius- Ethernet-Edition" included<br />

RS232 instead of USB<br />

USB connection cable for computer interface<br />

Weight Rating PK Cat. No.<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

9.868 000<br />

9.868 001<br />

6.232 520<br />

9.867 729<br />

9.867 730<br />

9.867 725<br />

9.867 713<br />

9.867 727<br />

7.082 551<br />

9.867 720<br />

9.867 722<br />

9.867 724