7. Heating and cooling technology<br />

Temperature regulators/Thermostats, cryostats<br />

1 2<br />

3 4<br />

1 2 3 4<br />

Forte HT30-M1 and Forte HT60-M2<br />

700<br />

High Temperature Circulators<br />

Julabo High Temperature Circulators have a compact, closed design and are ideally suited for wide working temperature ranges.<br />

- rapid heating<br />

- high pump capacity, reducible via adapter<br />

- small footprint<br />

- minimal filling volume<br />

- cooling water connections for applications at particularly high temperatures (cooling zone in unit)<br />

- wide working temperature range without changing bath fluids<br />

- avoids oxidation and cracking of the bath fluid. This ensures a prolonged lifetime of the bath fluids recommended by Julabo<br />

- can be easily integrated into a miniplant installation<br />

- time-saving filling process for the entire system with permanent air purge<br />

Forte HT30-M1 and Forte HT60-M2 with C.U. cooling unit<br />

E & OE.<br />

www.wenk-labtec.com<br />

GENERAL CATALOGUE 2010/11<br />

Using the optional C.U. cooling unit, the working temperature range can be further extended downwards. Additionally a high cooling capacity is available if<br />

constant tap water cooling is carried out.<br />

- temperature applications from +40°C with controlled tap water cooling<br />

- rapid cooling to low temperature values<br />

- dynamic control characteristics: Automatic control of exothermic reactions in the connected system<br />

Type Temp.<br />

range<br />

Forte HT30-M1<br />

Forte HT60-M2<br />

Forte HT30-M1-C.U.<br />

Forte HT60-M2-C.U.<br />

Temp.<br />

stability<br />

Heating<br />

capacity, kW<br />

Pump<br />

cap.<br />

°C ± °C L/min / bar<br />

+70 to +400<br />

+70 to +400<br />

+40 to +400<br />

+40 to +400<br />

±0.01 to ± 0.1<br />

±0.01 to ±0.1<br />

±0.01 to ± 0.1<br />

±0.01 to ± 0.1<br />

3<br />

7<br />

3<br />

7<br />

14 - 18 at 0.8 - 1.2<br />

14 - 18 at 0.8 - 1.2<br />

14 - 18 at 0.8 - 1.2<br />

14 - 18 at 0.8 - 1.2<br />

JULABO<br />

PK Cat. No.<br />

1<br />

1<br />

1<br />

1<br />

9.858 400<br />

6.300 656<br />

6.222 575<br />

9.858 404