GENERAL CATALOGUE 2010/11<br />

1<br />

7. Heating and cooling technology<br />

Heating/Incubators, drying cabinets, test chambers, hybridization chambers<br />

Safety vacuum drying ovens for flammable solvents, VDL series<br />

The VDL series with its extended package of safety features ensures maximum safety<br />

when drying organic solvents in accordance with TÜV/GS guidelines. The interior<br />

chamber is designed in accordance with the ATEX Directive for Zone 2, but the VDL series can also be equipped in<br />

accordance with the explosion risk requirements for zone 2 explosion hazard areas.<br />

Performance features and equipment:<br />

- Electronically controlled APT.line preheating chamber technology<br />

- Temperature range: 15°C (59°F) above ambient temperature up to 200°C ( 392°F)<br />

- MP controller with 2 programmes each with 10 segments, or alternatively 1 programme with 20 segments<br />

- Digital temperature setting with an accuracy of one or tenth of a degree<br />

- Integrated 7-day programme timer with real time function<br />

- Spring-mounted safety glass pane with splinter protection<br />

- Adjustable heat output (0 to 100 %)<br />

- Pressure monitor for controlled heat release at < 125 mbar (94 torr)<br />

- Pressure encapsulated instrument compartment with controlled overpressure by means of compressed air<br />

- Flame protection gasket<br />

- Ventilation bleed needle valve<br />

- Inert gas needle valve with cross-flow technology<br />

- Spring-mounted safety glass pane with splinter protection<br />

- Analogue pressure gauge (displays pressure difference between the inner chamber and the ambient pressure)<br />

- Electro polished inner chamber<br />

- All vacuum and vent tubing, as well as the internally-welded pressure container, the removable rack support and the<br />

vacuum valve are made of stainless steel Mat. No. 1.4571 (V4A)/AISI 316 Ti<br />

- Door gasket made of tempered silicone<br />

- Independent adjustable temperature safety device, Class 2 (DIN 12880), with visual temperature alarm<br />

- DN 16 measuring port in rear wall<br />

- RS 232 printer and communications interface for APT-COM DataControlSystem communication software<br />

- with 2 aluminium shelf racks<br />

Type Internal Internal<br />

External<br />

volume dimensions<br />

dimensions<br />

(W x D x H)<br />

(W x D x H)<br />

litres mm mm<br />

VDL 23<br />

23 285 x 285 x 285 515 x 500 x 655<br />

VDL 53<br />

53 400 x 330 x 400 634 x 550 x 775<br />

VDL 115<br />

115 506 x 450 x 506 740 x 670 x 900<br />

VDL 23 EX<br />

23 285 x 285 x 285 515 x 727 x 655<br />

VDL 53 EX<br />

53 400 x 330 x 400 634 x 777 x 775<br />

VDL 115 EX<br />

115 506 x 450 x 506 740 x 897 x 900<br />

E & OE.<br />

www.wenk-labtec.com<br />

1<br />

BINDER<br />

Description PK Cat. No.<br />

Standard<br />

Standard<br />

Standard<br />

EX-Zone 2<br />

EX-Zone 2<br />

EX-Zone 2<br />

925 117<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

9.883 531<br />

9.883 532<br />

9.883 533<br />

9.883 518<br />

9.883 519<br />

9.883 520<br />

741