GENERAL CATALOGUE 2010/11<br />

Accessories for Universal ovens E- and P- series<br />

Extended temperature range option, maximum 300°C - Universal ovens<br />

(Not available for models with full glass door).<br />

7. Heating and cooling technology<br />

Heating/Incubators, drying cabinets, test chambers, hybridization chambers<br />

E & OE.<br />

www.wenk-labtec.com<br />

Memmert<br />

Type Cl. PK Cat. No.<br />

A0 200<br />

A0 300<br />

A0 400<br />

A0 500<br />

A0 550<br />

A0 600<br />

A0 700<br />

A0 800<br />

E, P<br />

E, P<br />

E, P<br />

E, P<br />

E, P<br />

E, P<br />

E, P<br />

E, P<br />

Accessories for Universal ovens, E- and P- series<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

9.868 520<br />

9.868 530<br />

9.868 540<br />

9.868 550<br />

9.868 555<br />

9.868 560<br />

9.868 570<br />

9.868 580<br />

Special equipment. Memmert<br />

Type Cl. Description PK Cat. No.<br />

Q1<br />

Q2<br />

Q2<br />

Q3<br />

V1<br />

V4<br />

V9<br />

W3<br />

W4<br />

1<br />

E, P<br />

E, P 200/300<br />

E, P 400/500/550/600/700/800<br />

P<br />

P<br />

P<br />

P<br />

E, P<br />

P<br />

Cooled incubators, series IPP and ICP<br />

IQ check list with works test data<br />

for unit as support for validation<br />

by customer<br />

OQ check list, including temperature<br />

distribution survey to DIN 12880: 2007-05<br />

at 9 measuring points<br />

OQ check list, including temperature<br />

distribution survey to DIN 12880: 2007-05<br />

at 27 measuring points<br />

Extra for FDA conformance software,<br />

"Celsius FDA-Edition"<br />

Oven-linked authorisation card<br />

(user ID card)<br />

additional MEMory Card<br />

additional SeriCard (only for<br />

interior-sterilization) for incubators<br />

USB interface instead of RS232<br />

Ethernet interface instead of RS232. Software<br />

"Celsius-Ethernet-Edition" included<br />

The innovations of the new Perfect Line have been transplanted into Memmert cooled<br />

Memmert<br />

incubators as well. With fuzzy logic-supported, multifunctional, PID-microprocessor<br />

controller, 2 x high quality DIN-class A, 4-wire circuit, Pt100 probes allowing simultaneous monitoring and control<br />

functions, digital real time clock with weekly programmer and daily schedule function, protocol timer for temperature<br />

profiles of up to 40 ramps, with 1 min up to 999 h segments; programmable with an 8-digit, alphanumeric display<br />

(selection of language via set-up) also used for visualizing data during operation.<br />

An internal datalogging memory with a capacity of 1024 kB provides tamper-proof, storage and output of GLPcompliant,<br />

archive documentation of all relevant data. Includes an output interface with real time clock for PCL3compatible<br />

printers, RS 232 interface incl."Celsius 2007 Software " and 32 kB MEMory Card.<br />

For total safety, a multi-level overtemperature protection (MLOP) system is provided, with audiovisual alarm system,<br />

microprocessor temperature selector (MTS), protection class 3.3, for over- and undertemperature and additional<br />

integral Automatic Safety Function ASF for high and low temperature limits, automatically monitoring the set<br />

temperature and warning by an alarm when there is a temperature-related malfunction. In addition, the ICP series<br />

has a TB class 1 mechanical temperature control unit which activates when the actual temperature exceeds 10°C<br />

above it's setting.<br />

Proven Memmert quality: Textured 1.4301 stainless steel housing and stainless steel chamber guarantees corrosionresistance,<br />

easy cleaning and sanitization<br />

With additional inner glass door.<br />

Calibration certificate available on request at +10°C and +37°C<br />

Supply requirements: 230 V ±10% 50 Hz<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

1<br />

333<br />

9.867 698<br />

9.867 699<br />

9.867 693<br />

9.867 700<br />

9.867 701<br />

9.867 714<br />

9.867 702<br />

9.867 717<br />

9.867 718<br />

733