FAULT FINDING GUIDE (Cont'd)<br />
TROUBLE PROBABLE CAUSE REMEDY<br />
d. Film rubs on loop<br />
restorer arm<br />
e. Excessive film<br />
slap<br />
f. Animation clutch<br />
does not operate<br />
(Des. <strong>642</strong> only)<br />
g. Animation clutch<br />
stops sprocket but<br />
shuttle pulls film<br />
(Des. <strong>642</strong> only)<br />
h. Splices jam in<br />
sprocket shoes<br />
Restorer arm out of position Reposition (para. 52b)<br />
Damaged film<br />
Dirty gate<br />
Pressure shoe rubbing on<br />
edge guides<br />
Incorrect shuttle stroke<br />
Open circuit<br />
Solenoid plunger set too high<br />
or too low<br />
Stop pawl clearance excessive<br />
Recondition or replace<br />
Clean<br />
Realign<br />
Adjust (para. 43e)<br />
Repair<br />
Adjust<br />
Adjust (para. 46a)<br />
Insufficient shuttle retraction Adjust (para. 46b)<br />
Bad splices<br />
Sprocket shoes set too close<br />
6. SOUND SYSTEM TROUBLES AND REMEDIES<br />
Replace<br />
Adjust (para. 44)<br />
TROUBLE PROBABLE CAUSE REMEDY<br />
a. <strong>Projector</strong> runs,<br />
valve 8 do not<br />
light<br />
b. Valves light,<br />
exciter does<br />
not light<br />
Loose connection<br />
Valve burnt out<br />
Exciter lamp cable<br />
disconnected<br />
Wrong exciter lamp used<br />
Damaged oscillator valve<br />
<strong>Projector</strong> switch open or<br />
leads disconnected<br />
9<br />
Repair<br />
Replace<br />
Connect cable<br />
Replace with correct lamp<br />
Replace<br />
Replace switch or connect<br />
leads