Basic setting chemicals<br />
Set adjustment cover to 2%.<br />
Remove the service tool and reconnect<br />
the hose to the washing area to the distributor<br />
block air.<br />
Repeat the setting of the dosing valves<br />
air for the remaining washing areas.<br />
Note<br />
After performing the basic setup, the consistency<br />
of the foam should only be<br />
changed by adjusting the dosing valves air.<br />
Controls<br />
If no faults are present, nothing will be<br />
shown.<br />
Note<br />
To acknowledge faults see "Fault assistance"<br />
Open the menu "customer settings"<br />
Press OK button for more than 2 seconds.<br />
Press the RIGHT button.<br />
1 Output air<br />
2 Distributor block water/chemicals<br />
3 Water/chemicals dosing valve<br />
4 Output water/chemicals<br />
5 Distribution block air<br />
6 Dosing valve air<br />
Open fresh water supply.<br />
Remove the hose at the distribution<br />
block water/chemicals outlet and replace<br />
with a 400 mm hose piece (PVC<br />
hose 6/4).<br />
Use wash programme "Foam wash" for<br />
this washing area.<br />
Set the fluid stream from the hose piece<br />
by adjusting the dosing valve water/<br />
chemicals to 300 ml/min (measure with<br />
measuring cylinder).<br />
End wash programme "foam wash".<br />
Remove the hose piece and reconnect<br />
the hose to the washing area.<br />
Repeat the setting of the dosing valves<br />
water/chemicals for the remaining<br />
washing areas.<br />
Basic setting air<br />
1 Key "1/ON"<br />
2 Control lamp operating state<br />
3 Display<br />
4 LEFT key<br />
5 RIGHT key<br />
6 OK button<br />
7 ESC button<br />
During normal operating mode, the control<br />
panel display alternates between:<br />
Day of the week, date, time, summer time<br />
(Som)/winter time (Wint)<br />
Press the OK button.<br />
The menu "customer settings" (see following<br />
page) has been reached.<br />
Operating time of the system on the current<br />
day<br />
1 Pressure reducer<br />
Set pressure reducer to 0.25 MPa (2.5<br />
bar).<br />
Use the service tool 6.901-074.0 between<br />
the output on the distributor block<br />
air and the hose to the washing area.<br />
Use wash programme "Foam wash" for<br />
this washing area.<br />
Adjust the dosing valve air so that the<br />
pressure gauge of the service tool displays<br />
0.15 MPa (1.5 bar).<br />
End wash programme "foam wash".<br />
Maintenance work due from customer service<br />
(example).<br />
If more than one maintenance procedure is<br />
required, these will be shown in sequence.<br />
If no maintenance procedures are required,<br />
nothing will be shown.<br />
Fault occurred (example).<br />
If more than one fault is present, these will<br />
be shown in sequence.<br />
The number in parentheses shows the total<br />
number of faults present.<br />