Time Activity Assembly affected Performance By whom<br />
many times<br />
daily<br />
opinion Washing brush Check for dirt and ice formation; lock foam wash if needed. Operator<br />
daily opinion Hot blowers Are the hot air ventilators working (even for ABS fuel tank, option)? Operator<br />
Initially daily,<br />
later on<br />
based on experience<br />
opinion<br />
Filling level of the fuel<br />
tank<br />
Will the heating oil be sufficient till next inspection? Take into account<br />
increased consumption due to anti-frost equipment. Insufficient<br />
fuel can lead to failure and damage to the system.<br />
Operator<br />
Once, 1<br />
week after<br />
start-up<br />
monthly or<br />
after 200 operating<br />
hours; more<br />
frequently if<br />
needed<br />
Clean<br />
the filter<br />
Clean<br />
the filter<br />
opinion<br />
Dirt collector of the washing<br />
place heating (Option)<br />
Filter for frost-protection<br />
pump<br />
Quantity of frost water<br />
protection in the frost<br />
protection circuit<br />
Close locking tap. Screw on the dirt collector. Remove the sieve<br />
inlay and clean it. Reassemble in reverse sequence and open the<br />
locking valve. Refill heating circuit and deaerate (see section on<br />
"Plant installation/ Washing place heating attachment set").<br />
Clean the filter and replace<br />
Target value: approx. 0.5 l/min per washing tool<br />
Water quantity is higher: Change the node piece in the hand-spray<br />
gun.<br />
Water quantity is lesser Clean filter for frost protection pump; clean<br />
sieve in throttle, clean pipes, check the rotation direction of the<br />
pump.<br />
Shutting down<br />
Turn the main switch to position "0"<br />
Shutdown during Frost Conditions<br />
Operator<br />
Operator<br />
Operator<br />
In case of doubt, call Customer Service to<br />
carry out the shutdown operations.<br />
1 Locking valve<br />
2 Dirt catcher<br />
1 Throttle with sieve (marked red), 1-toolmodel<br />
1 Throttle with sieve (marked red), 2-toolmodel<br />
(option)<br />
<strong>SB</strong>-C...<strong>Wso</strong><br />
Shutdown the plant if there is frost.<br />
<strong>SB</strong>-C...<strong>Wso</strong> <strong>Fp</strong><br />
Turn the main switch to position "1".<br />
Lock the operating time at the control.<br />
Refill fuel tank.<br />
Shutdown<br />
If the equipment is to be shut down, and<br />
there is not danger of frost,<br />
disconnect the water input,<br />
disconnect the power supply.<br />
Shutdown during frost period<br />
Screw off water supply hose and high<br />
pressure hose.<br />
Remove the RO membrane and store it<br />
under anti-freezing conditions.<br />
Empty all swimmer containers; unscrew<br />
the hoses and let the water drain off.<br />
Empty the permeate buffer tank.<br />
Disconnect the water pipe between<br />
base exchanger and swimmer tank for<br />
warm water.<br />
Rinse the plant (without base exchanger)<br />
with an anti-frost solution.<br />
Rinse the base exchanger with concentrated<br />
salt solution.<br />
Unscrew both the hoses under the boiler<br />
and let the water drain off.<br />
Blow out all water-carrying parts with<br />
oil-free compressed air.<br />
Note<br />
All parts of the plant except the base exchanger<br />
must be rinsed with anti-frost solution<br />
during longer operational breaks to<br />
prevent the system against corrosion.<br />
English 49