Template BA B168xH238 - Hörmann
Template BA B168xH238 - Hörmann
Template BA B168xH238 - Hörmann
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
ENGLISH<br />
13<br />
Overview of DIL Switch Functions<br />
DIL A DIL B Function Option relay function<br />
OFF ON CLOSE limit switch reporting activated The relay picks up in the CLOSE end-of-travel<br />
position (CLOSE reporting function)<br />
ON OFF Pre-warning time activated Relay clocks rapidly during the pre-warning<br />
time and normally during the door run (warning<br />
lamp function)<br />
OFF OFF External light activated Relay the same as operator light (external light<br />
function)<br />
DIL A DIL B DIL D Function Option relay function<br />
ON ON ON Automatic timed closing activated,<br />
photocell must be installed<br />
Relay clocks rapidly during the<br />
pre‐warning time, normally during the<br />
travel phase and has permanent contact<br />
during the hold-open phase<br />
DIL C<br />
ON<br />
OFF<br />
Door type<br />
Up-and-over door, long soft-stop ramp-down phase<br />
Sectional door, short soft-stop ramp-down phase<br />
DIL D<br />
ON<br />
OFF<br />
Photocell<br />
Photocell is activated, after triggering the photocell, the door reverses to the OPEN end-of-travel position<br />
(automatic timed closing is only possible with a photocell)<br />
Photocell not activated (automatic timed closing not possible)<br />
DIL E<br />
ON<br />
OFF<br />
Stop circuit with self testing<br />
Wicket door contact with self-testing activated. The self-testing is checked before each door run<br />
(operation only possible with a wicket door contact that can be tested)<br />
Safety device without self-testing<br />
DIL F<br />
ON<br />
OFF<br />
Door maintenance display<br />
Activated, exceeding the maintenance cycle is signalled by the operator light flashing at the end of every<br />
door run<br />
Not activated, no signal after the maintenance cycle is exceeded<br />
TR10A033-E RE / 03.2010 37