Ultrasonic flow sensor - Hachflow

Ultrasonic flow sensor - Hachflow

Ultrasonic flow sensor - Hachflow

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Error listErrors may occur for various reasons. The reading on the measurementscreen flashes. All outputs are held when specified in the controllermenu. To show the <strong>sensor</strong> errors, push the MENU key and selectDiagnostics, [Select Sensor], Error List. A list of possible errors is shownin Table 5.Table 5 Error list for the <strong>sensor</strong>Error Description ResolutionSENSOR MISSINGWarning listThe <strong>sensor</strong> is missing ordisconnectedExamine the wiring andconnections for the<strong>sensor</strong> and for themodule.A warning does not affect the operation of menus, relays and outputs. Awarning icon flashes and a message is shown on the bottom of themeasurement screen. To show the <strong>sensor</strong> warnings, push the MENUkey and select Sensor Diag, [Select Sensor], Warning List. A list ofpossible warnings is shown in Table 6.Table 6 Warning list for the <strong>sensor</strong>Warning Description ResolutionTOTALIZER FULLTEMP WARNINGThe <strong>sensor</strong>volume/totalizer is full.The temperature is out ofscope.Reset the <strong>sensor</strong>volume/totalizer.Replace the <strong>sensor</strong>.ECHO MISSING The echo signal is lost. Option 1—Move the<strong>sensor</strong> closer to thewater surface.Option 2—Adjust the<strong>sensor</strong> mounting toproperly aim the <strong>sensor</strong>at the water surface.Option 3—Replace the<strong>sensor</strong>.Table 6 Warning list for the <strong>sensor</strong> (continued)Warning Description ResolutionEXCESS LEVELREPLACE SENSORCAL DUENOT CALIBRATEDCAL IN PROGRESSOUTPUTS ON HOLDEvent listThe excess level is out ofrange.The <strong>sensor</strong> needs to bereplaced.The <strong>sensor</strong> calibration isover due.The <strong>sensor</strong> needs to becalibrated.The calibration wasstarted but notcompleted.During calibration, theoutputs were set to holdfor a selected time.Option 1—Make sure thegauge type is correct.Option 2—Calibrate the<strong>sensor</strong>.Replace the <strong>sensor</strong>.Calibrate the <strong>sensor</strong>.Calibrate the <strong>sensor</strong>.Return to calibration.The outputs will becomeactive after the selectedtime period.The controller provides one event log for each <strong>sensor</strong>. The event logstores a variety of events that occur on the devices such as configurationchanges, alarms, warning conditions, etc. A list of possible events isshown in Table 7. The event log can be read out in a CSV format. Forinstructions on downloading the logs, see the controller user manual.EventPOWER ON EVENTCHANGE IN CONFIG - floatCHANGE IN CONFIG - intCHANGE IN CONFIG - textTable 7 Event list for the <strong>sensor</strong>DescriptionThe power was turned on.The configuration changed-floating numberThe configuration changed-integer numberThe configuration changed-text stringEnglish 17

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!