7.2 Compressor maintenance<br />
Caution: Before the start of any maintenance work, the<br />
mains plug must be unplugged.<br />
Note: Please note the details in the compressor operations<br />
diary<br />
Filter cleaning every three months<br />
1. Unscrew the attachment screw on the filter lid.<br />
2. Detach/undo the filter lid.<br />
3. Remove the filter. Release any dust by knocking the filter<br />
against something. If it is heavily soiled, clean the filter<br />
with a neutral detergent, afterwards rinse with water and<br />
allow to dry in the shade.<br />
4. Refit the cleaned filter such that the finer honeycomb<br />
structure is located on the bottom side! Press the filter lid<br />
back into place by exerting pressure from above.<br />
5. Fasten the filter lid with the screw.<br />
Caution! Do not use any solvents to clean the filter, as<br />
this may lead to damage.<br />
In general, the following must be checked:<br />
- Is any air flowing from the air outlet?<br />
- Can any abnormal noises or vibrations be heard?<br />
- Is the compressor's temperature normal or possibly<br />
excessive?<br />
- Does the mains power supply cable exhibit any damage?<br />
7. Maintenance<br />
7.3 Diagnosis and faults<br />
In case of complaints, please first of all refer to chapter 10<br />
"Malfunctions and Remedial Measures".<br />
If it is nevertheless not possible to eliminate a fault, separate<br />
the plant from the power supply and contact one of our<br />
dealers or after-sales service technicians. When doing so,<br />
communicate details of the components (rating plate) and<br />
faults as detailed as possible.<br />
Warning:<br />
Do not put the plant back into operation before a possible<br />
fault has been eliminated. Do not undertake any further attempts<br />
at repairing the plant yourself! Repairs must be carried<br />
out by qualified personnel. If you have any queries in respect<br />
of service work, please contact one of our dealers or<br />
after-sales service technicians.<br />
Spare parts<br />
Please use exclusively original parts.<br />
Failure to do so may lead to malfunctions or defects on the<br />
compressor.<br />
Observe the separate installation and operating instructions<br />
with regard to maintaining the normal service intervals for the<br />
compressor. You can obtain a spare parts list from the aftersales<br />
service of <strong>KESSEL</strong>.<br />