9. Malfunctions and remedial measure faults<br />

Faults Causes Elimination<br />

Battery voltage too high<br />

Relay error<br />

The display of the control<br />

does not show anything or shows<br />

the message "Mains failure"<br />

The display shows the<br />

message "Extraction"<br />

Other possible faults<br />

The water level in the preliminary<br />

sedimentation is exceptionally<br />

high, while the aeration exhibits a<br />

normal water level<br />

The water level in the preliminary<br />

sedimentation and in the aeration<br />

is exceptionally high<br />

- Battery not available<br />

- Battery contact error<br />

- Relay contact in control unit is<br />

stuck together<br />

- The plant is currentless<br />

- The display is defective<br />

- Maximum extraction time too<br />

short<br />

- Uncontrolled inflow to the plant<br />

(e.g. rain water, plant leaks)<br />

- Water cannot drain off (e.g.<br />

backup, compressed air syphon<br />

hose not in drain)<br />

- Floating switch too low (setting<br />

see floating switch)<br />

- Excessive impact load on plant<br />

- Compressed air syphon for the<br />

feeding is clogged<br />

- Plant undersized<br />

- Mains failure<br />

- Exceedingly high external water<br />

inflow. In case of heavy rainfalls<br />

due to surface water or on soaked<br />

soils due to a leaky tank.<br />

- Compressor does not work<br />

- Compressed air syphon for clear<br />

water extraction is clogged<br />

- Pressure hose leaky or no longer<br />

connected.<br />

126<br />

- Insert a battery<br />

- Check battery polarity and seat<br />

- Replace the control unit<br />

- Check pre-fuse and / or earth leakage<br />

circuit breaker<br />

- Call after-sales service, adapt<br />

maximum extraction time<br />

- Ensure that there is no inflow of<br />

external water into the plant<br />

- Provide free drainage.<br />

- Replace the floating switch<br />

- Control the impact load<br />

- If it is not possible to restore the<br />

function even during longer manual<br />

operation, remove the compressed<br />

air syphon and rinse<br />

clean<br />

- Adapt the inflow quantities or expand<br />

the plant<br />

- Connect the plant to the grid<br />

- External water may not penetrate<br />

into sewage treatment plants<br />

for a longer period of time. If necessary<br />

seal concrete tank or<br />

eliminate other causes.<br />

- Check function in manual mode.<br />

If it is not possible to start up the<br />

compressor, call the after-sales<br />

service.<br />

- If it is not possible to restore the<br />

function even during longer manual<br />

operation, remove the compressed<br />

air syphon and rinse<br />

clean.<br />

- Check connections and pressure<br />

hose and if necessary restore