5.2 Fitting to the structure<br />

Fitting to masonry:<br />

• Only dowels permitted <strong>und</strong>er building regulations<br />

requirements may be used for masonry.<br />

• Where the base material cannot be identified, a system<br />

for affixing the ladder system is to be agreed with the<br />

designer of the supporting structure.<br />

• It is also possible to anchor the system through the<br />

masonry using a counter plate. This is to be discussed<br />

and verified with the structural engineer.<br />

Fitting to concrete structures:<br />

• Only dowels permitted <strong>und</strong>er building regulations<br />

requirements may be used for concrete structures.<br />

• Where the base material cannot be identified, a system<br />

for affixing the ladder system is to be agreed with the<br />

designer of the supporting structure.<br />

• Concrete category = C 20 - 25<br />

• Dowel pull-out strength = ≥ 12 kN<br />

Recommended dowel for fixing to concrete structures:<br />

HILTI HST-R M16<br />

Ensure that the torques for the dowels used for<br />

affixing the ladder are observed.<br />

Fitting to steel structures:<br />

• Fitting the anchor point to existing lugs.<br />

The anchorage point is secured using bolts<br />

(M16, property class 8.8).<br />

• The bolts must be tightened with a torque<br />

of 210 Nm.<br />

• DIN 985 or DIN 980-compliant lock nuts are<br />

approved for securing the bolts.<br />

Alternatively, a liquid threadlocker, such as Loctite,<br />

can be used.<br />

• In all cases, ensure that the anchor point has been<br />

fitted as specified and that it is secured to the<br />

structure/gro<strong>und</strong> according to the specifications.<br />