6. Technical data 7. Care, maintenance, inspection<br />

Manufacturer:<br />

Hailo Wind Systems GmbH & Co. KG<br />

Daimlerstraße 2, 35708 Haiger, Germany<br />

<strong>Universal</strong> anchorage point – performance data<br />

Nominal work load limit (WLL)<br />

22,24 kN<br />

No. of persons max. 2<br />

Bolts for securing anchor point M16 - 8.8<br />

Torque M 16 - 8.8<br />

Dowel pull-out strength<br />

Dowel torque<br />

+49 (0) 2773 82-0<br />

+49 (0) 2773 82-1561<br />

E-Mail: info@ hailo-windsystems.de<br />

Website: www.hailo-windsystems.com<br />

210 Nm<br />

≥ 12 kN<br />

Please refer to the information<br />

provided by the relevant manufacturer<br />

Dimensions of the universal anchorage point:<br />

• Any contamination is to be cleaned off with clean water,<br />

removing the remaining water with a dry cloth.<br />

• Make sure that the universal anchorage point does not<br />

come into contact with acids or any other fluids.<br />

• The user must carry out a visual and manual inspection<br />

of the universal anchorage point each time before it is<br />

used.<br />

• Check that all the components are correctly secured and<br />

that no distortion, damage, cracks or other defects of<br />

any kind can be identified.<br />

• The wear sustained by equipment does of course depend<br />

on the length of service and type of use to which it is<br />

put. It is therefore difficult to state what the exact<br />

service life will be as it depends on the extent and<br />

frequency of use and on the environment in which it is<br />

used.<br />

In order to guarantee the safety of the anchorage<br />

point, the fitting and all the components must be<br />

inspected at intervals of at least once a year based<br />

on the stress imposed during use. This inspection must<br />

be carried out by a trained/authorised person using the<br />

inspection schedule provided in these instructions for<br />

fitting and use.<br />

The anchorage point must also be inspected in the event<br />

of damage and following any exceptional events.<br />