Montage- und Gebrauchsanleitung Universal Anschlagpunkt 115
Montage- und Gebrauchsanleitung Universal Anschlagpunkt 115
Montage- und Gebrauchsanleitung Universal Anschlagpunkt 115
Sie wollen auch ein ePaper? Erhöhen Sie die Reichweite Ihrer Titel.
YUMPU macht aus Druck-PDFs automatisch weboptimierte ePaper, die Google liebt.
5. Fitting the universal anchorage point<br />
5.3 Fitting to a fixed vertical ladder<br />
IMPORTANT: The operating licence will be<br />
revoked and all warranties on the part of manufacturer<br />
invalidated if this device is not handled in<br />
accordance with these instructions (i.e. improper<br />
assembly or fitting, surface damage, etc.).<br />
The universal anchorage point is approved for fi tting to<br />
Hailo aluminium vertical ladders, type ALO 72 MA/BA.<br />
When fi tting to ladders supplied by other manufacturers,<br />
the designer must verify that the required stability<br />
is available for absorbing the forces generated in<br />
the event of a fall. The ladder must be designed and<br />
installed to meet EN ISO 14122-4 requirements.<br />
The universal anchorage point is fi tted to 5 ladder<br />
rungs with various fi xtures.<br />
1) 3 ladder rungs are fi rst reinforced using a rung<br />
repair kit [1].<br />
Push a tube [1a] into each rung and secure it on both<br />
sides with an adjusting screw [1c] and countersunk<br />
screw M16x50 [1b].<br />
Torque to be applied to screws: 80 Nm<br />
2) Secure the U profi le [2] to the 1st and 5th rungs of the<br />
ladder from behind using the U bolt set [5].<br />
Torque: 20 Nm<br />
3) Secure the location plate [3] to the 3 middle rungs<br />
from the front using the U bolt set [5].<br />
Torque: 20 Nm<br />
4) Fit the anchorage point [4] to the location plate<br />
(M16x50 bolts, DIN 933, property class 8.8 [6]).<br />
Torque: 210 Nm<br />
The position of the location plate on the ladder can be varied.<br />
The anchorage point can be fi tted in the centre or on the side of<br />
the ladder. Ensure that the specifi ed tread widths are observed.<br />
Attached on the side:<br />
X = min. 300 mm<br />
Attached in the centre:<br />
X = min. 150 mm<br />
When carrying out the annual inspection of the<br />
anchorage point, the bolts and screws must be<br />
checked to ensure that they are screwed tight.<br />
30<br />