5. Fitting the universal anchorage point<br />
5.4 Fitting to a fixed vertical ladder with a Hailo or Haca fall protection rail<br />
IMPORTANT: The operating licence will be<br />
revoked and all warranties on the part of manufacturer<br />
invalidated if this device is not handled in<br />
accordance with these instructions (i.e. improper<br />
assembly or fitting, surface damage, etc.).<br />
The components supplied for fi tting the universal<br />
anchorage point allow it to be fi tted to a fi xed<br />
vertical ladder with fall protection rails of different<br />
manufacturers.<br />
The location plate is secured to the rung using<br />
additional components with the fall protection rail.<br />
If a fall protection rail fi xture is already in place<br />
where the location plate needs to be fi tted, the<br />
existing fi xture must be removed and replaced<br />
according to the assembly steps 1-4.<br />
Installation example:<br />
The universal anchorage point is fi tted to 3 ladder<br />
rungs using various fi xtures together with the<br />
fall protection rail.<br />
1) 3 ladder rungs are fi rst reinforced using a<br />
rung repair kit [1].<br />
Push a tube [1a] into each rung and secure it on both<br />
sides with an adjusting screw [1c] and countersunk<br />
screw M16x50 [1b].<br />
Torque to be applied to screws: 80 Nm<br />
2) Position the location plate [2] on these 3 rungs<br />
from behind. Together with the fall protection rail,<br />
the location plate is secured to the rungs using<br />
3 mounting sets [4].<br />
Torque: 20 Nm<br />
3) Fit the anchorage point [3] to the location plate<br />
(M16x50 bolts, DIN 933, property class 8.8 [5]).<br />
Torque: 210 Nm<br />
4) In addition to this, the fall protection rail is secured to<br />
the next rung above and the next rung below the<br />
location plate using a mounting set [4].<br />
Ensure that the specifi ed<br />
tread widths are observed.<br />
X = min. 150 mm<br />
When carrying out the annual inspection of the<br />
anchorage point, the bolts and screws must be<br />
checked to ensure that they are screwed tight.<br />