5. Fitting the universal anchorage point<br />

5.4 Fitting to a fixed vertical ladder with a Hailo or Haca fall protection rail<br />

IMPORTANT: The operating licence will be<br />

revoked and all warranties on the part of manufacturer<br />

invalidated if this device is not handled in<br />

accordance with these instructions (i.e. improper<br />

assembly or fitting, surface damage, etc.).<br />

The components supplied for fi tting the universal<br />

anchorage point allow it to be fi tted to a fi xed<br />

vertical ladder with fall protection rails of different<br />

manufacturers.<br />

The location plate is secured to the rung using<br />

additional components with the fall protection rail.<br />

If a fall protection rail fi xture is already in place<br />

where the location plate needs to be fi tted, the<br />

existing fi xture must be removed and replaced<br />

according to the assembly steps 1-4.<br />

Installation example:<br />

The universal anchorage point is fi tted to 3 ladder<br />

rungs using various fi xtures together with the<br />

fall protection rail.<br />

1) 3 ladder rungs are fi rst reinforced using a<br />

rung repair kit [1].<br />

Push a tube [1a] into each rung and secure it on both<br />

sides with an adjusting screw [1c] and countersunk<br />

screw M16x50 [1b].<br />

Torque to be applied to screws: 80 Nm<br />

2) Position the location plate [2] on these 3 rungs<br />

from behind. Together with the fall protection rail,<br />

the location plate is secured to the rungs using<br />

3 mounting sets [4].<br />

Torque: 20 Nm<br />

3) Fit the anchorage point [3] to the location plate<br />

(M16x50 bolts, DIN 933, property class 8.8 [5]).<br />

Torque: 210 Nm<br />

4) In addition to this, the fall protection rail is secured to<br />

the next rung above and the next rung below the<br />

location plate using a mounting set [4].<br />

Ensure that the specifi ed<br />

tread widths are observed.<br />

X = min. 150 mm<br />

When carrying out the annual inspection of the<br />

anchorage point, the bolts and screws must be<br />

checked to ensure that they are screwed tight.<br />

32<br />

Instructions for fitting and use • <strong>Universal</strong> anchorage point • Revised 2013-11/GB/02