4-times option for torch trigger.Permit to define 3 different waysto control the torch trigger when themachine is set as 4Times stroke (Lift orHF). For detailed description of differentbehaviours see the following diagrams.Select a value in the range 0...2 (1=defaultsetting).Dynamic Oxide Control(for <strong>AC</strong> welding)0 = disabled1 = enabled (factory settings)Remote Control OptionIt is possible to select 4 differentways depending from the external deviceconnected to 8-pole plug(option)Welding current can be controlled up toprevious SET or to MAX.External reference voltage can be 0-10V or0-5V (Condition 2 & 3 presents lowerresolution)0 = 0-10V Imin to ISET (factory settings)1 = 0-10V Imin to IMAX2 = 0-5V Imin to ISET3 = 0-5V Imin to IMAXAll above settings are not modified via Reset.26