B<br />
Floor/Ceilings<br />
Steel Framed<br />
1-1/2 Hour <strong>Fire</strong>-rated Construction Steel Bar Joist Framing (Refer to ULC/UL Design Directory listings for loading conditions. See page 6.) Acoustical Performance Reference<br />
Construction Detail Description Test Number STC Test Number ARL Index<br />
551 mm<br />
(21 11 ⁄16")<br />
• 15.9 mm (5/8�) or 19.1 mm (3/4�) FR-83 or UL Des G267 SC2000 B-7<br />
19.1 mm (3/4�) AP-3 or FR-X1 acoust ceiling panels<br />
• DXL, DXLZ or SDXL Susp Exp Grid System<br />
– light fixture, air duct and speakers optional<br />
– 64 mm (2-1/2�) concrete on corrugated steel deck<br />
– steel bar joists<br />
2 Hour <strong>Fire</strong>-rated Construction<br />
clg. wt. 3 • 12.7 mm (1/2�) or 15.9 mm (5/8�) SHEETROCK ULC Des I507 <strong>SA</strong>920 B-8<br />
FIRECODE C Core Gypsum Panels or UL Des G515<br />
352 mm<br />
(13<br />
– metal furring channel 610 mm (24�) o.c.<br />
– joints finished<br />
– 64 mm (2-1/2�) concrete on riblath or corrugated<br />
steel deck<br />
– steel bar joists<br />
• optional veneer plaster<br />
7 54* ASTM E1414<br />
*CAC value per ASTM E1414 test<br />
⁄8")<br />
procedure for horizontally adjacent<br />
spaces<br />
clg. wt. 2 • 15.9 mm (5/8�) SHEETROCK FIRECODE ULC Des I508 53 NGC-4075<br />
B-9<br />
Core Gypsum Panels<br />
– steel bar joists 610 mm (24�) o.c.<br />
– metal furring channel, 300 mm (12�) o.c.<br />
or UL Des G503<br />
406 mm<br />
(16")<br />
533 mm<br />
(21")<br />
609 mm<br />
(24")<br />
533 mm<br />
(21")<br />
609 mm<br />
(24")<br />
• 12.7 mm (1/2�) or 15.9 mm (5/8�) SHEETROCK UL Des G523 SC2000 B-10<br />
Gypsum Panels, FIRECODE C Core<br />
• <strong>CGC</strong> DGL Drywall Suspension System<br />
– joints finished<br />
– 64 mm (2-1/2�) concrete on riblath or steel deck<br />
– steel bar joists, 610 mm (24�) o.c.<br />
– 3 hr. rating with 15.9 mm (5/8�) panels and<br />
75 mm (3�) thick concrete<br />
• optional veneer plaster<br />
• <strong>CGC</strong> DGL Drywall Suspension System UL Des G526 SC2000 B-11<br />
• 12.7 mm (1/2�) or 15.9 mm (5/8�) SHEETROCK<br />
FIRECODE C Core Gypsum Panels<br />
– joints finished<br />
– 64 mm (2-1/2�) concrete on riblath<br />
– steel bar joists, 610 mm (24�) o.c.<br />
• optional veneer plaster<br />
26 <strong>CGC</strong> <strong>Fire</strong>-<strong>Resistant</strong> <strong>Assemblies</strong>